CoChat

Measuring orthostatic hypotension with the Finometer device: is a blood pressure drop of one heartbeat clinically relevant?

van der Velde, Nathalie, van den Meiracker, Anton H., Stricker, Bruno H.Ch., van der Cammen, Tischa J.M. · 2007 · Blood Pressure Monitoring
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The role of orthostatic hypotension in falls in older people is generally accepted. Because of the high degree of intra- and interobserver variability in conventional measurements of orthostatic hypotension, application of continuous measurement systems has been proposed. The clinical relevance of a blood pressure drop lasting one heartbeat, however, is unknown. We therefore investigated which time average of continuous-finger-blood-pressure measurement (Finometer) showed the best association between orthostatic hypotension and falls. This was also compared with conventional sphygmomanometer measurements. METHODS: In 217 geriatric outpatients supine and standing (finger) blood pressure to diagnose orthostatic hypotension was monitored with Finometry (beat-to-beat and 1, 5, 10, 15, 20 and 30 s averages) and sphygmomanometry. History of fall incidents (previous year) was registered. RESULTS: The best association (C=0.22, P=0.003) with falls history was found for the 5-s average of Finometry, whereas falls and orthostatic hypotension assessed by sphygmomanometry did not correlate. The odds ratio of a fall according to orthostatic hypotension using the 5-s average was 2.54 (95% CI: 1.37 to 4.71). CONCLUSIONS: Orthostatic hypotension and falls are correlated when using Finometry, with the best association found when using 5-s averages. As the etiology of falls is often multifactorial, orthostatic hypotension and falls are poorly correlated, irrespective of the method or time average that is applied.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e3280b083bd

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
van der Velde, N., van den Meiracker, A. H., Stricker, B. H. C., & van der Cammen, T. J. M.
Venue
Blood Pressure Monitoring
Published
2007-06
Volume
12
Issue
3
Pages
167-171
ISSN
1359-5237 (ISSN-L)
OpenAlex
W1995578373
Cited by
70
References
3
FWCI
2.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.