OBJECTIVE: Older adults with chronic kidney disease have a high rate of uncontrolled hypertension. Home monitoring of blood pressure (BP) is an integral part of management, but requires that patients bring records to clinic visits. Telemonitoring interventions, however, have not targeted older, less technologically-skilled populations. METHODS: Veterans with stage 3 or greater chronic kidney disease and uncontrolled hypertension were randomized to a novel telemonitoring device pairing a Bluetooth-enabled BP cuff with an Internet-enabled hub, which wirelessly transmitted readings (n=28), or usual care (n=15). Home recordings were reviewed weekly and telemonitoring participants were contacted if BP was above goal. The prespecified primary endpoints were improved data exchange and device acceptability. Secondary endpoint was BP change. RESULTS: Forty-three participants (average age 68 years, 75% white) completed the 6-month study. Average start-of-study BP was 147/78 mmHg. Those in the intervention arm had a median of 29 (IQR 22, 53) transmitted BP readings per month, with 78% continuing to use the device regularly, whereas only 20% of those in the usual care group brought readings to in-person visits. The median number of telephone contacts triggered by the wireless monitoring was 2 (IQR 1, 4) per patient. Both groups had a significant improvement in systolic BP (P<0.05, for both changes); systolic BP fell a median of 13 mmHg in monitored participants compared with 8.5 mmHg in usual care participants (P for comparison 0.31). CONCLUSION: This low-cost wireless monitoring strategy led to greater sharing of data between patients and clinic and produced a trend toward improvements in BP control over usual care at 6 months.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e32835d126c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 93

Metadata

Authors
Rifkin, D. E., Abdelmalek, J. A., Miracle, C. M., Low, C., Barsotti, R., Rios, P., Stepnowsky, C., & Agha, Z.
Venue
Blood Pressure Monitoring
Published
2013-02
Volume
18
Issue
1
Pages
8-15
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2033420720
Cited by
93
References
2
FWCI
2.89
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Linking clinic and home: a randomized, controlled clinical effectiveness trial of real-time, wireless blood pressure monitoring for older patients with kidney disease and hypertension. https://app.cochat.ai/papers/10.1097/mbp.0b013e32835d126c
The paper
Rifkin, D. E., Abdelmalek, J. A., Miracle, C. M., Low, C., Barsotti, R., Rios, P., Stepnowsky, C., & Agha, Z. (2013). Linking clinic and home: a randomized, controlled clinical effectiveness trial of real-time, wireless blood pressure monitoring for older patients with kidney disease and hypertension. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e32835d126c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.