Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

What is a fluid challenge?

Cecconi, Maurizio, Parsons, Anthony K, Rhodes, Andrew · 2011 · Current Opinion in Critical Care

Abstract

PURPOSE OF REVIEW: The fluid challenge is used in the fluid management of many sick patients. The principle behind the fluid challenge technique is that by giving a small amount of fluid in a short period of time, the clinician can assess whether the patient has a preload reserve that can be used to increase the stroke volume with further fluids. The key components of a fluid challenge are described. RECENT FINDINGS: Dynamic predictors of fluid responsiveness are increasingly used in preference to the central venous and pulmonary artery occlusion pressure. The gold standard to monitor the response to a fluid challenge is using a continuous cardiac output monitoring. Fluid therapy guided by flow monitoring has been shown to reduce hospital stay and postoperative complications. SUMMARY: A fluid challenge identifies and simultaneously treats volume depletion, whilst avoiding deleterious consequences of fluid overload through its small volume and targeted administration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mcc.0b013e32834699cd

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 244

Metadata

Authors
Cecconi, M., Parsons, A. K., & Rhodes, A.
Venue
Current Opinion in Critical Care
Published
2011-06
Volume
17
Issue
3
Pages
290-295
ISSN
1070-5295 (ISSN-L)
OpenAlex
W2317570550
Cited by
244
References
1
FWCI
10.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.