The DOI matches its Crossref record.
Patient Factors Predictive of Inadequate Bowel Preparation Using Polyethylene Glycol: A Prospective Study in Korea
Abstract
BACKGROUND: Inadequate bowel preparation is important because it can result in missed lesions, cancelled procedures, increased procedural time, and a potential increase in complication rates. This prospective study was designed to look at the quality of colon preparation using polyethylene glycol solution and evaluate potential associations between specific patient characteristics and inadequate bowel preparation. METHODS: A total of 362 patients who were compliant with preparation instructions were enrolled. All colonoscopic examinations were performed by an experienced endoscopist and the quality of the preparation was graded by the endoscopist (excellent to poor). Patient demographic and medical history information was gathered before the procedure. Possible predictors of inadequate colonic preparation were analyzed using univariate statistics and multivariate logistic regression models. RESULTS: An inadequate bowel preparation was reported in 28.2% of observed colonoscopies. In multivariate regression analysis, age greater than 60 years [odds ratio (OR) 2.8, 95% confidence interval (CI) 1.04-7.4], a history of diabetes (OR 8.6, 95% CI 6.3-19.4), a history of appendectomy (OR 4.6, 95% CI 2.0-10.5), a history of colorectal resection (OR 7.5, 95% CI 3.4-17.6), and a history of hysterectomy (OR 3.4, 95% CI 1.1-10.4) were independent predictors of an inadequate colon preparation. CONCLUSIONS: This prospective study identified several factors that may predict inadequate polyethylene glycol preparation independent of compliance with preparation instructions and procedure starting time. This result may help to identify patients at an increased risk for inadequate bowel preparation for whom alternative preparation protocols would be beneficial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Johnson, D. A., Barkun, A. N., Cohen, L. B., Dominitz, J. A., Kaltenbach, T., Martel, M., Robertson, D. J., Boland, C. R., Giardello, F. M., Lieberman, D. A., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.07.002 · Cited by 492
Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
Hassan, C., Bretthauer, M., Kaminski, M., Polkowski, M., Rembacken, B., Saunders, B., Benamouzig, R., Holme, O., Green, S., Kuiper, T., et al. (2013) · Endoscopy · doi:10.1055/s-0032-1326186 · Cited by 458
Hassan, C., Fuccio, L., Bruno, M., Pagano, N., Spada, C., Carrara, S., Giordanino, C., Rondonotti, E., Curcio, G., Dulbecco, P., et al. (2012) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2011.12.037 · Cited by 282
Bessissow, T., Van Keerberghen, C.-A., Van Oudenhove, L., Ferrante, M., Vermeire, S., Rutgeerts, P., & Van Assche, G. (2013) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2013.04.011 · Cited by 53
Metadata
- Authors
- Chung, Y. W., Han, D. S., Park, K. H., Kim, K. O., Park, C. H., Hahn, T., Yoo, K.-S., Park, S. H., Kim, J. H., & Park, C. K.
- Venue
- Journal of Clinical Gastroenterology
- Published
- 2009-05
- Volume
- 43
- Issue
- 5
- Pages
- 448-452
- ISSN
- 0192-0790 (ISSN-L)
- OpenAlex
- W2090862970
- Cited by
- 180
- References
- 0
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patient Factors Predictive of Inadequate Bowel Preparation Using Polyethylene Glycol: A Prospective Study in Korea. https://app.cochat.ai/papers/10.1097/mcg.0b013e3181662442
- The paper
- Chung, Y. W., Han, D. S., Park, K. H., Kim, K. O., Park, C. H., Hahn, T., Yoo, K.-S., Park, S. H., Kim, J. H., & Park, C. K. (2009). Patient Factors Predictive of Inadequate Bowel Preparation Using Polyethylene Glycol: A Prospective Study in Korea. Journal of Clinical Gastroenterology. https://doi.org/10.1097/mcg.0b013e3181662442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.