Frequency of HbA1c discordance in estimating blood glucose control
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: HbA1c is a trusted standard for monitoring glycemic control and predicting complications. However, there are emerging issues complicating the interpretation of HbA1c that the clinician caring for patients with diabetes needs to consider. RECENT FINDINGS: There is increasing evidence of the potential for mismatches between HbA1c and other measures of glycemia which require some caution in HbA1c interpretation. We have attempted to characterize the nature of these discordances by developing the concept of the 'glycation gap' in which differences in protein glycation occurring in the intracellular space (HbA1c) versus in the extracellular space (measured as fructosamine) are compared. We have evidence that HbA1c results discordant from other measures of glycemic control may be secondary to previously unappreciated physiological variables, including erythrocyte lifespan, in hematologically normal individuals. We relate these findings to a number of HbA1c interpretation issues important for diabetes care: factors affecting hemoglobin glycation, relationship of HbA1c to glycemia, standardization of the HbA1c assay, and HbA1c relation to complications. SUMMARY: There are an increasing number of clinical circumstances in which there are nuances to HbA1c interpretation such that standard norms for assessment of glycemic control or complication risk may need to be modified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Herman, W. H., Ma, Y., Uwaifo, G., Haffner, S., Kahn, S. E., Horton, E. S., Lachin, J. M., Montez, M. G., Brenneman, T., Barrett-Connor, E., et al. (2007) · Diabetes Care · doi:10.2337/dc06-2003 · Cited by 574
Relationship between glycated haemoglobin levels and mean glucose levels over time
Nathan, D. M., Turgeon, H., & Regan, S. (2007) · Diabetologia · doi:10.1007/s00125-007-0803-0 · Cited by 517
Glycemic Variability: A Hemoglobin A1c–Independent Risk Factor for Diabetic Complications
Brownlee, M., & Hirsch, I. B. (2006) · JAMA · doi:10.1001/jama.295.14.1707 · Cited by 482
Nonenzymatic glycosylation of protein: relevance to diabetes
Bunn, H. F. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90769-5 · Cited by 171
Rosiglitazone and cardiotoxicity –weighing the evidence
Nathan, D. M. (2007) · New England Journal of Medicine · doi:10.1056/nejme078117 · Cited by 126
Cited by
A1c versus glucose testing: a comparison
Sacks, D. B. (2011) · Diabetes Care · doi:10.2337/dc10-1546 · Cited by 461
Relationship Between A1C and Glucose Levels in the General Dutch Population
van 't Riet, E., Alssema, M., Rijkelijkhuizen, J. M., Kostense, P. J., Nijpels, G., & Dekker, J. M. (2010) · Diabetes Care · doi:10.2337/dc09-0677 · Cited by 199
“The amount of glycosylation is known to vary interindividually (16,17).”
Cheng, Y. J., Gregg, E. W., Geiss, L. S., Imperatore, G., Williams, D. E., Zhang, X., Albright, A. L., Cowie, C. C., Klein, R., & Saaddine, J. B. (2009) · Diabetes Care · doi:10.2337/dc09-0440 · Cited by 157
“Glycation rate is also influenced by factors other than the level of plasma glucose (20).”
Background
Metadata
- Authors
- Cohen, R. M., & Smith, E. P.
- Venue
- Current Opinion in Clinical Nutrition and Metabolic Care
- Published
- 2008-07
- Volume
- 11
- Issue
- 4
- Pages
- 512-517
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2152932258
- Cited by
- 58
- References
- 6
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency of HbA1c discordance in estimating blood glucose control. https://app.cochat.ai/papers/10.1097/mco.0b013e32830467bd
- The paper
- Cohen, R. M., & Smith, E. P. (2008). Frequency of HbA1c discordance in estimating blood glucose control. Current Opinion in Clinical Nutrition and Metabolic Care. https://doi.org/10.1097/mco.0b013e32830467bd
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.