Cardiac device implantation in Fabry disease: A retrospective monocentric study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The incidence and predictive factors of arrhythmias and/or conduction abnormalities (ACAs) requiring cardiac device (CD) implantation are poorly characterized in Fabry disease (FD). The aim of our retrospective study was to determine the prevalence, incidence, and factors associated with ACA requiring CD implantation in a monocentric cohort of patients with confirmed FD who were followed up in a department of internal medicine and reference center for FD.Forty-nine patients (20M, 29F) were included. Nine patients (4M, 5F; 18%) had at least one episode of ACA leading to device therapy. Six patients (4M/2F) required a pacemaker (PM) for sinus node dysfunction (n = 4) or atrioventricular disease (n = 2). One female patient required an internal cardioverter-defibrillator (ICD) to prevent sudden cardiac death because of nonsustained ventricular tachycardia (nSVT). One female patient required PM-ICD for sinus node dysfunction and nSVT. One patient underwent CD implantation before the diagnosis of FD. The annual rate of CD implantation was estimated at 1.90 per 100 person years. On univariate analysis at the end of the follow-up period, the factors associated with ACAs requiring CD implantation were as follows: delayed diagnosis of FD, delayed initiation of enzyme replacement therapy, age at the last follow-up visit, and severe multiorgan phenotype (hypertrophic cardiomyopathy, chronic kidney disease, and/or sensorineural hearing loss). On multivariate analysis, age at diagnosis of FD and age at the last follow-up visit were independently associated with an increased risk of ACAs requiring CD (P < 0.05).Considering the high frequency of ACAs requiring CD implantation and the risk of sudden death in patients with FD, regular monitoring is mandatory, especially in patients with a late diagnosis of FD and/or with a severe phenotype. Regular Holter ECGs, therapeutic education of patients, and deliverance of an emergency card including a phenotype summary are crucial in the care of FD patients.Available guidelines for device therapy and the efficacy of enzyme replacement therapy for arrhythmias or conduction abnormalities are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy
Authors/Task Force members, Elliott, P. M., Anastasakis, A., Borger, M. A., Borggrefe, M., Cecchi, F., Charron, P., Hagege, A. A., Lafont, A., Limongelli, G., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu284 · Cited by 4,332
Self-citation
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
An Expert Consensus Document on the Management of Cardiovascular Manifestations of Fabry Disease
Linhart, A., Germain, D. P., Olivotto, I., Akhtar, M. M., Anastasakis, A., Hughes, D., Namdar, M., Pieroni, M., Hagège, A., Cecchi, F., et al. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1960 · Cited by 230
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 160
Metadata
- Authors
- Sené, T., Lidove, O., Sebbah, J., Darondel, J.-M., Picard, H., Aaron, L., Fain, O., Zenone, T., Joly, D., Charron, P., & Ziza, J.-M.
- Venue
- Medicine
- Published
- 2016-10
- Volume
- 95
- Issue
- 40
- Pages
- e4996
- ISSN
- 0025-7974 (ISSN-L)
- OpenAlex
- W2528387682
- Cited by
- 28
- References
- 1
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac device implantation in Fabry disease: A retrospective monocentric study. https://app.cochat.ai/papers/10.1097/md.0000000000004996
- The paper
- Sené, T., Lidove, O., Sebbah, J., Darondel, J.-M., Picard, H., Aaron, L., Fain, O., Zenone, T., Joly, D., Charron, P., & Ziza, J.-M. (2016). Cardiac device implantation in Fabry disease: A retrospective monocentric study. Medicine. https://doi.org/10.1097/md.0000000000004996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.