The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Lung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis
Open accessAbstract
BACKGROUND: Pneumonia is a common and serious infectious disease that can cause high mortality. The role of lung ultrasound (LUS) in the diagnosis of pneumonia is becoming more and more important. METHODS: In the present study, we collected existing evidence regarding the use of LUS to diagnose pneumonia in adults and conducted a systematic review to summarize the technique's diagnostic accuracy. We specifically searched the Cochrane Central Register of Controlled Trials (CENTRAL), PubMed, and Embase databases and retrieved outcome data to evaluate the efficacy of LUS for the diagnosis of pneumonia compared with chest radiography or chest computed tomography. The pooled sensitivity (SEN) and specificity (SPE) were determined using the Mantel-Haenszel method, and the pooled diagnostic odds ratio (DOR) was determined using the DerSimonian-Laird method. We also assessed heterogeneity of sensitivity, specificity, and diagnostic odds ratio using the Q and I statistics. RESULTS: Twelve studies containing 1515 subjects were included in our meta-analysis. The SEN and SPE were 0.88 (95% CI: 0.86-0.90) and 0.86 (95% CI: 0.83-0.88), respectively. The pooled negative likelihood ratio (LR) was 0.13 (95% CI: 0.08-0.23), the positive LR was 5.37 (95% CI: 2.76-10.43), and the DOR was 65.46 (95% CI: 29.24-146.56). The summary receiver operating characteristic curve indicated a relationship between sensitivity and specificity. The area under the curve for LUS was 0.95. CONCLUSION: LUS can help to diagnose adult pneumonia with high accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
Cited by
Torres, A., Cilloniz, C., Niederman, M. S., Menéndez, R., Chalmers, J. D., Wunderink, R. G., & van der Poll, T. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00259-0 · Cited by 798
Streptococcus pneumoniae’s Virulence and Host Immunity: Aging, Diagnostics, and Prevention
Brooks, L. R. K., & Mias, G. I. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.01366 · Cited by 286
Amatya, Y., Rupp, J., Russell, F. M., Saunders, J., Bales, B., & House, D. R. (2018) · International Journal of Emergency Medicine · doi:10.1186/s12245-018-0170-2 · Cited by 137
Metadata
- Authors
- Long, L., Zhao, H.-T., Zhang, Z.-Y., Wang, G.-Y., & Zhao, H.-L.
- Venue
- Medicine
- Published
- 2017-01
- Volume
- 96
- Issue
- 3
- Pages
- e5713
- ISSN
- 0025-7974 (ISSN-L)
- OpenAlex
- W2574256306
- Cited by
- 169
- References
- 3
- FWCI
- 11.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis. https://app.cochat.ai/papers/10.1097/md.0000000000005713
- The paper
- Long, L., Zhao, H.-T., Zhang, Z.-Y., Wang, G.-Y., & Zhao, H.-L. (2017). Lung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis. Medicine. https://doi.org/10.1097/md.0000000000005713
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.