Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Molecular Diagnosis of Infective Endocarditis by Real-Time Broad-Range Polymerase Chain Reaction (PCR) and Sequencing Directly From Heart Valve Tissue

Marín, Mercedes, Muñoz, Patricia, Sánchez, Mónica, del Rosal, Marina, Alcalá, Luis, Rodríguez-Créixems, Marta, Bouza, Emilio·2007·Medicine

Abstract

Traditionally, infective endocarditis (IE) has been microbiologically diagnosed by blood cultures or serology. However, conventional microbiologic methods do not always provide an etiologic diagnosis. We conducted the current study to evaluate the usefulness of a universal real-time polymerase chain reaction (PCR) of the 16S rRNA gene followed by sequencing for the diagnosis of IE in explanted heart valve tissue (HV) as part of the routine of a clinical microbiology laboratory, and to compare it with conventional culture of blood or HV. We prospectively analyzed 177 HV samples by universal PCR and sequencing: 48 were from 35 patients with definite IE and 129 were from 120 patients without IE. Specific PCR tests were used when necessary to confirm broad-range PCR results. For the 35 patients with IE, all of the HV samples except for 2 from the same patient gave positive PCR results. The microorganisms identified matched those isolated by blood culture in 31 cases. The other 3 patients had negative blood culture IE, but PCR made possible the detection of Tropheryma whipplei, Bartonella quintana, and Streptococcus gallolyticus. For the negative control group, universal PCR was completely negative in 123 of the 129 samples. Sensitivity, specificity, and negative and positive predictive values of this real-time PCR method were 96%, 95.3%, 98.4%, and 88.5%, respectively, for the diagnosis of IE, using the Duke criteria to define IE and using blood culture results to identify etiologic microorganisms. Conventional HV culture correlated poorly with blood cultures and molecular techniques, and frequently represented tissue contamination resulting from valve handling. Our universal PCR method has proved to be more sensitive, specific, and rapid than conventional culture methods, and should therefore be included as a new major Duke criterion for the diagnosis of IE. According to the results of the current study, this technique should be used to supplement blood and HV culture. Conventional HV cultures are frequently responsible for false-positive and false-negative results, and are not always useful to establish the etiology of IE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/md.0b013e31811f44ec

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 162

Metadata

Authors
Marín, M., Muñoz, P., Sánchez, M., del Rosal, M., Alcalá, L., Rodríguez-Créixems, M., & Bouza, E.
Venue
Medicine
Published
2007-07
Volume
86
Issue
4
Pages
195-202
ISSN
0025-7974 (ISSN-L)
OpenAlex
W2037363213
Cited by
162
References
1
FWCI
7.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Molecular Diagnosis of Infective Endocarditis by Real-Time Broad-Range Polymerase Chain Reaction (PCR) and Sequencing Directly From Heart Valve Tissue. https://app.cochat.ai/papers/10.1097/md.0b013e31811f44ec
The paper
Marín, M., Muñoz, P., Sánchez, M., del Rosal, M., Alcalá, L., Rodríguez-Créixems, M., & Bouza, E. (2007). Molecular Diagnosis of Infective Endocarditis by Real-Time Broad-Range Polymerase Chain Reaction (PCR) and Sequencing Directly From Heart Valve Tissue. Medicine. https://doi.org/10.1097/md.0b013e31811f44ec

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.