Management of respiratory motion in PET/computed tomography: the state of the art
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Combined PET/computed tomography (CT) is of value in cancer diagnosis, follow-up, and treatment planning. For cancers located in the thorax or abdomen, the patient's breathing causes artifacts and errors in PET and CT images. Many different approaches for artifact avoidance or correction have been developed; most are based on gated acquisition and synchronization between the respiratory signal and PET acquisition. The respiratory signal is usually produced by an external sensor that tracks a physiological characteristic related to the patient's breathing. Respiratory gating is a compensation technique in which time or amplitude binning is used to exclude the motion in reconstructed PET images. Although this technique is performed in routine clinical practice, it fails to adequately correct for respiratory motion because each gate can mix several tissue positions. Researchers have suggested either selecting PET events from gated acquisitions or performing several PET acquisitions (corresponding to a breath-hold CT position). However, the PET acquisition time must be increased if adequate counting statistics are to be obtained in the different gates after binning. Hence, other researchers have assessed correction techniques that take account of all the counting statistics (without increasing the acquisition duration) and integrate motion information before, during, or after the reconstruction process. Here, we provide an overview of how motion is managed to overcome respiratory motion in PET/CT images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Werner, M. K., Parker, J. A., Kolodny, G. M., English, J. R., & Palmer, M. R. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2516 · Cited by 100
Cited by
PET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“In fact, motion cannot be predicted in advance, since it depends on the specific patient and on the specific anatomical district [89, 90].”
BackgroundInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
“Several techniques for respiratory motion correction have been proposed [89].”
MethodSchulz, A., Godt, J. C., Dormagen, J. B., Holtedahl, J. E., Bogsrud, T. V., Labori, K. J., Kløw, N.-E., & Bach-Gansmo, T. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.05.011 · Cited by 3
Metadata
- Authors
- Pépin, A., Daouk, J., Bailly, P., Hapdey, S., & Meyer, M.-E.
- Venue
- Nuclear Medicine Communications
- Published
- 2014-02
- Volume
- 35
- Issue
- 2
- Pages
- 113-122
- ISSN
- 0143-3636 (ISSN-L)
- OpenAlex
- W2087247947
- Cited by
- 112
- References
- 2
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Management of respiratory motion in PET/computed tomography: the state of the art. https://app.cochat.ai/papers/10.1097/mnm.0000000000000048
- The paper
- Pépin, A., Daouk, J., Bailly, P., Hapdey, S., & Meyer, M.-E. (2014). Management of respiratory motion in PET/computed tomography: the state of the art. Nuclear Medicine Communications. https://doi.org/10.1097/mnm.0000000000000048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.