CoChat

Validation of an electronic image reader training programme for interpretation of [18F]flutemetamol β-amyloid PET brain images

Open access
Buckley, Christopher J., Sherwin, Paul F., Smith, Adrian P.L., Wolber, Jan, Weick, Sharon M., Brooks, David J. · 2017 · Nuclear Medicine Communications
Cited by 69

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: An electronic training programme (ETP) was developed for interpretation of images during routine clinical use of the PET amyloid imaging agent [F]flutemetamol injection (VIZAMYL). This study was carried out to validate the ETP. MATERIALS AND METHODS: Five nuclear medicine technologists (NMTs) and five readers previously inexperienced in amyloid image interpretation were required to self-train using the ETP and pass a test to participate. A total of 305 [F]flutemetamol PET images were then tested as the validation set, following preassessment and reorientation (where required) by one of five NMTs. Next, a new set of readers blinded to clinical information independently assessed all 305 images. Images had been acquired in previous studies from patients representing the full spectrum of cognitive capacity. When available, a standard of truth determined by histopathology or clinical history was used to derive sensitivity and specificity for image interpretation from this validation set. Randomly selected images (n=29) were read in duplicate to measure intrareader reproducibility. Images were read first without, and subsequently with anatomic images, if available. RESULTS: All NMTs and all readers scored 100% on the qualifying test. The interpretation of 135 cases without anatomic image support resulted in sensitivity ranging from 84% to 94% (majority 94%, median 92%) and specificity ranging from 77% to 96% (majority 92%, median 81%). Inter-reader agreement was very high, with most κ scores more than 0.8. Intrareader reproducibility ranged from 93 to 100%. CONCLUSION: The self-guided ETP effectively trained new amyloid PET image readers to accurately and reproducibly interpret [F]flutemetamol PET images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mnm.0000000000000633

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 69

Metadata

Authors
Buckley, C. J., Sherwin, P. F., Smith, A. P. L., Wolber, J., Weick, S. M., & Brooks, D. J.
Venue
Nuclear Medicine Communications
Published
2017-03
Volume
38
Issue
3
Pages
234-241
ISSN
0143-3636 (ISSN-L)
OpenAlex
W2567492225
Cited by
69
References
7
FWCI
3.42
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of an electronic image reader training programme for interpretation of [18F]flutemetamol β-amyloid PET brain images. https://app.cochat.ai/papers/10.1097/mnm.0000000000000633
The paper
Buckley, C. J., Sherwin, P. F., Smith, A. P. L., Wolber, J., Weick, S. M., & Brooks, D. J. (2017). Validation of an electronic image reader training programme for interpretation of [18F]flutemetamol β-amyloid PET brain images. Nuclear Medicine Communications. https://doi.org/10.1097/mnm.0000000000000633

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.