Abstract
PURPOSE: The aim of this article was to systematically review all the available ophthalmic patient-reported outcome (PRO) instruments (questionnaires) that demonstrated interval measurement properties to identify the instruments with the highest psychometric quality for use in different eye diseases and conditions. METHODS: An extensive literature review was carried out to identify all existing ophthalmic PRO instruments. Instruments were then excluded if they did not have demonstrable interval measurement properties; the remaining instruments were reviewed. The quality of the following psychometric properties was assessed: content development (initial item development process), performance of the response scale, dimensionality (whether the instrument measures a single construct), measurement precision, validity (convergent, concurrent, discriminant, and known groups), reliability (test-retest), targeting (whether the items are appropriate [e.g., difficulty level] for the population), differential item functioning (whether subgroups of people respond differently to an item), and responsiveness. RESULTS: The search identified 48 PRO instruments that demonstrated interval measurement properties, and these were relevant to nine applications: glaucoma, dry eye, refractive errors, cataract, amblyopia and strabismus, macular diseases, adult low vision, children low vision, and others. These instruments were evaluated against the psychometric property quality criteria and were rated for quality based on the number of criteria met. CONCLUSIONS: This review provides a descriptive catalog of ophthalmic PRO instruments to inform researchers and clinicians on the choice of the highest-quality PRO instrument suitable for their purpose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mokkink, L. B., Terwee, C. B., Patrick, D. L., Alonso, J., Stratford, P. W., Knol, D. L., Bouter, L. M., & de Vet, H. C. W. (2010) · Quality of Life Research · doi:10.1007/s11136-010-9606-8 · Cited by 4,260 · cited 2×
“More recently, an international initiative (Consensus-based Standards for the selection of health status Measurement Instruments [COSMIN]) has put forward a standardized scoring system for assessing the quality of PRO instruments based on nine metric properties.(19,20) The quality criteria we have used in this study a…”
MethodDevelopment of the 25-list-item National Eye Institute Visual Function Questionnaire
Mangione, C. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.1050 · Cited by 2,230
Mokkink, L. B., Terwee, C. B., Knol, D. L., Stratford, P. W., Alonso, J., Patrick, D. L., Bouter, L. M., & de Vet, H. C. (2010) · BMC Medical Research Methodology · doi:10.1186/1471-2288-10-22 · Cited by 1,834
The VF-14: An Index of Functional Impairment in Patients With Cataract
Steinberg, E. P. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090170074026 · Cited by 960
Development of the Activities of Daily Vision Scale: A Measure of Visual Functional Status
Mangione, C. M., Phillips, R. S., Seddon, J. M., Lawrence, M. G., Cook, E. F., Dailey, R., & Goldman, L. (1992) · Medical Care · doi:10.1097/00005650-199212000-00004 · Cited by 539
Mangione, C. M., Berry, S., Spritzer, K., Janz, N. K., Klein, R., Owsley, C., & Lee, P. P. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.2.227 · Cited by 486
McAlinden, C., Pesudovs, K., & Moore, J. E. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5341 · Cited by 451 · cited 1×
“It is a superior-quality instrument and had high quality across all the assessment criteria (Table 2).(42) The QoV was developed to measure visual symptoms in groups of spectacle wearers, contact lens wearers, patients who had postrefractive surgery (including intraocular surgery), and patients who had cataract.”
BackgroundSelf-citationThe Development, Assessment, and Selection of Questionnaires
PESUDOVS, K., BURR, J. M., HARLEY, C., & ELLIOTT, D. B. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e318141fe75 · Cited by 403 · cited 9×
“The quality of a PRO instrument is determined by a large number of criteria that include steps taken in the development and identification of the initial content to testing the validity and reliability.(4) Validity refers to the extent to which a PRO instrument measures the underlying concept it is supposed to measure.”
BackgroundMethodSelf-citationQuality of Life in Glaucoma and Its Relationship with Visual Function
Nelson, P., Aspinall, P., Papasouliotis, O., Worton, B., & O'Brien, C. (2003) · Journal of Glaucoma · doi:10.1097/00061198-200304000-00009 · Cited by 387
Lai, J.-S., Cella, D., Choi, S., Junghaenel, D. U., Christodoulou, C., Gershon, R., & Stone, A. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.08.033 · Cited by 362
Metadata
- Authors
- Khadka, J., McAlinden, C., & Pesudovs, K.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-08
- Volume
- 90
- Issue
- 8
- Pages
- 720-744
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W1985381226
- Cited by
- 226
- References
- 88
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Assessment of Ophthalmic Questionnaires: Review and Recommendations. https://app.cochat.ai/papers/10.1097/opx.0000000000000001
- The paper
- Khadka, J., McAlinden, C., & Pesudovs, K. (2013). Quality Assessment of Ophthalmic Questionnaires: Review and Recommendations. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000000001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.