The Effects of Age, Refractive Status, and Luminance on Pupil Size
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Purpose: Pupil size is critical for optimal performance of presbyopic contact lenses. Although the effect of luminance is well known, little information is available regarding other contributing factors such as aging and refractive status. Methods: The cohort population comprised 304 patients (127 male, 177 female) aged 18 to 78 years. Pupils were photographed at three controlled luminance levels 250, 50, and 2.5 cd/m 2 using an infra‐red macro video camera. Measurements of pupil diameter were conducted after transforming pixel values to linear values in millimeters. Results: Luminance was the most influential factor with pupil diameter increasing with decreased luminance (p < 0.001, all comparisons). Age was also found to be a significant factor with a smaller diameter in the older groups, but overall the difference was only significant between the pre‐presbyopes and the established presbyopes (p = 0.017). Pupil diameter decreased significantly with increasing age, the effect being most marked at low luminance (<0.001). The smallest pupil diameters were measured for hyperopes and the largest for myopes and although refractive error was not a significant factor alone, there was a significant interaction between luminance and refractive error with the greatest differences in pupil diameter between myopes and emmetropes at low luminance (p < 0.001). Pupil diameter changes modeled by multilinear regression (p < 0.001) identified age, luminance, best sphere refraction, and refractive error as significant factors accounting for just over 70% of the average variation in pupil diameter. Conclusions: Both age and refractive status were found to affect pupil size with larger pupils measured for younger patients and myopes. Designs for multifocal contact lens corrections should take both age and refractive status into consideration; a faster progression from distance to near corrections across the optical zone of the lens is expected to be required for established presbyopes and hyperopes than it is for early presbyopes, myopes, and emmetropes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It has also been confirmed that demographic variables, such as age, may influence the outcomes of pupillary assessments (20,21).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [20]
In the citing paper
“In addition, individual factors such as age, iris color, and physiological anisocoria have been emphasized as elements that further complicate interpretation during manual assessment (20,21).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [20]
In the citing paper
“With advancing age, a tendency toward reduced pupil diameter and an increased prevalence of anisocoria has been reported.”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [20]
In the citing paper
“Studies have indicated that in environments with excessive illumination, the light reflex may be excessively triggered, potentially going unnoticed by the examiner, thereby leading to inaccuracies in the assessment process (20,21,31,32,42,47).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [20]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1994) · PubMed · Cited by 688
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399 · cited 1×
“Extensive modeling of factors influencing pupil size has been conducted by Watson and Yellott who derived a unified formula for light adapted pupil diameter including the effects of luminance, adapting field size, age of the observer, and whether one or both eyes were used.(18) The authors did, however, provide a cave…”
MethodThe pupillary light reflex in normal subjects.
Ellis, C. J. (1981) · British Journal of Ophthalmology · doi:10.1136/bjo.65.11.754 · Cited by 292
Pupil Size as Determined by Adapting Luminance*
de Groot, S. G., & Gebhard, J. (1952) · Journal of the Optical Society of America · doi:10.1364/josa.42.000492 · Cited by 229
Birren, J. E., Casperson, R. C., & Botwinick, J. (1950) · Journal of Gerontology · doi:10.1093/geronj/5.3.216 · Cited by 206
Influences of Luminance and Accommodation Stimuli on Pupil Size and Pupil Center Location
Mathur, A., Gehrmann, J., & Atchison, D. A. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13492 · Cited by 86
Pupil Size in Refractive Surgery Candidates
Netto, M. V., Ambrósio, R., & Wilson, S. E. (2004) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20040701-06 · Cited by 77
Refractive Error May Influence Mesopic Pupil Size
Çakmak, H. B., Çağıl, N., Simavlı, H., Duzen, B., & Şimşek, Ş. (2010) · Current Eye Research · doi:10.3109/02713680903447892 · Cited by 72
Is Pupil Diameter Influenced by Refractive Error?
Orr, J. B., Seidel, D., Day, M., & Gray, L. S. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000627 · Cited by 59
Impact of contact lens zone geometry and ocular optics on bifocal retinal image quality
Bradley, A., Nam, J., Xu, R., Harman, L., & Thibos, L. N. (2014) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12110 · Cited by 55
Cited by
Items 201–223 of 223
Comparació del diàmetre pupil·lar entre miops i no miops
Barrouhou, Y. B. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Ferreira, M. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.17.2019.tde-29102018-155613
Objective and subjective evaluation of dysphotopsia in normal and post-operative eyes
Aujla, M. (2018) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00039105
Ishio, H., & Miyao, M. (2020) · International Conference on Computer Science & Education (ICCSE) · doi:10.1109/iccse49874.2020.9201877
The Effect of Night Glare on Myopia
Park, S.-H., & Jeon, ⋅.-C. (2020) · The Korean Journal of Vision Science · doi:10.17337/jmbi.2020.22.4.465
Yang, S., & Wang, Y. (2021) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.15029
Multifocal lens HDR image simulation showing dysphotopsia
Cvarch, B. A., & Schwiegerling, J. T. (2022) · Current Developments in Lens Design and Optical Engineering · doi:10.1117/12.2632381
Zhenlin, L., Gao, P., & Honghua, Z. (2022) · Research Square · doi:10.21203/rs.3.rs-2250508/v1
CLs for presbyopes: Reuseable multifocal
Ruston, D. M., Williby, G., & Moody, K. J. (2021) · Optician · doi:10.12968/opti.2021.7.238508
Self-citationThe Effect of Corneal Refractive Power on Refractive Errors and Pupil Diameter
Lim, D.-K., Kim, D.-Y., & Lee, K.-J. (2022) · The Korean Journal of Vision Science · doi:10.17337/jmbi.2022.24.4.381
First order solution generation for reflective dual-conjugate zoom systems
Teverovsky, D. S., Smith, K. A., & Bentley, J. (2024) · SPIE Optical Design and Engineering · doi:10.1117/12.3017603
Diagnostic utility of pupillometry in detecting autonomic dysfunction in migraine disorders
Türkoğlu, C., İşçan, D., & Arslan, E. (2025) · Çukurova medical journal (Online)/Çukurova medical journal · doi:10.17826/cumj.1658478
Expanding Horizons: Visual Outcomes with a 7.7 mm Optical Zone in KLEx Surgery
Beckers, D. D., Kretz, F. T. A., Höhn, F., Glandorf, K., Breyer, D. R. H., Messerschmidt‐Roth, A., & Beckers, L. (2025) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-2661-4897
Phatak, N., Reindel, W. T., Rah, M., Proskin, H. M., Giedd, K. K., & Pucker, A. D. (2025) · Clinical Optometry · doi:10.2147/opto.s513407
Huang, Y.-Y., & Menozzi, M. (2025) · Applied Optics · doi:10.1364/ao.562760
Harun, A. K. (1982) · Universiti Sains Malaysia Institutional Repository (Universiti Sains Malaysia)
Erigozzi, M. (2021) · Padua@thesis (Department of Information Engineering University of Padova)
Optical quality of Fresnel-structured hyperopic implantable collamer lenses: A ray-tracing analysis
Shimizu, K., & Kawamorita, T. (2026) · PLoS ONE · doi:10.1371/journal.pone.0345116
Visual Performance of Two Daily Disposable Multifocal Contact Lenses in Presbyopic Soft Lens Wearers
Stahl, U. G., Woods, J., Ng, A., Luensmann, D., & Jones, L. (2026) · Clinical ophthalmology · doi:10.2147/opth.s579245
Dilated pupil vertical-to-horizontal ratio as a predictor of intraoperative floppy-iris syndrome
Kakiuchi, H., Obata, S., Ohji, M., & Sawada, O. (2026) · Journal of Cataract & Refractive Surgery · doi:10.1097/j.jcrs.0000000000002068
Postoperative shifts in pupil position following cataract surgery
Mita, N., Ukai, Y., Mito, T., Seki, Y., Sasaki, Y., Sasaki, M., Miyashita, H., Shibuya, E., Kubo, E., & Sasaki, H. (2026) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-026-01425-1
Goh, Y. H., Choi, Y. S., Choi, S., Lim, D. H., Na, S.-J., & Nam, D. J. (2026) · Journal of Ophthalmology · doi:10.1155/joph/7762608
Clinical utility of pupil diameter cutoffs for detecting early presbyopia
Gettinger, K., Hanyuda, A., Kubota, M., Kubota, S., Masui, S., Ayaki, M., & Negishi, K. (2026) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-026-01431-3
Metadata
- Authors
- Guillon, M., Dumbleton, K., Theodoratos, P., Gobbe, M., Wooley, C. B., & Moody, K.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2016-09
- Volume
- 93
- Issue
- 9
- Pages
- 1093-1100
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2404073272
- Cited by
- 184
- References
- 18
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.