CoChat

Biomass Stoves and Lens Opacity and Cataract in Nepalese Women

Open access
Pokhrel, Amod K., Bates, Michael N., Shrestha, Sachet P., Bailey, Ian L., DiMartino, Robert B., Smith, Kirk R. · 2013 · Optometry and Vision Science
Cited by 55

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: Cataract is the most prevalent cause of blindness in Nepal. Several epidemiologic studies have associated cataracts with use of biomass cookstoves. These studies, however, have had limitations, including potential control selection bias and limited adjustment for possible confounding. This study, in Pokhara City, in an area of Nepal where biomass cookstoves are widely used without direct venting of the smoke to the outdoors, focuses on preclinical measures of opacity while avoiding selection bias and taking into account comprehensive data on potential confounding factors. METHODS: Using a cross-sectional study design, severity of lenticular damage, judged on the LOCS (Lens Opacities Classification System) III scales, was investigated in women (n = 143), aged 20 to 65 years, without previously diagnosed cataract. Linear and logistic regression analyses were used to examine the relationships with stove type and length of use. Clinically significant cataract, used in the logistic regression models, was defined as a LOCS III score ≥2. RESULTS: Using gas cookstoves as the reference group, logistic regression analysis for nuclear cataract showed evidence of relationships with stove type: for biomass stoves, the odds ratio was 2.58 (95% confidence interval, 1.22 to 5.46); and for kerosene stoves, the odds ratio was 5.18 (95% confidence interval, 0.88 to 30.38). Similar results were found for nuclear color (LOCS III score ≥2), but no association was found with cortical cataracts. Supporting a relationship between biomass stoves and nuclear cataract was a trend with years of exposure to biomass cookstoves (p = 0.01). Linear regression analyses did not show clear evidence of an association between lenticular damage and stove types. Biomass fuel used for heating was not associated with any form of opacity. CONCLUSIONS: This study provides support for associations of biomass and kerosene cookstoves with nuclear opacity and change in nuclear color. The novel associations with kerosene cookstove use deserve further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0b013e3182820d60

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Pokhrel, A. K., Bates, M. N., Shrestha, S. P., Bailey, I. L., DiMartino, R. B., & Smith, K. R.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2013-03
Volume
90
Issue
3
Pages
257-268
ISSN
1040-5488 (ISSN-L)
OpenAlex
W2091654848
Cited by
55
References
3
FWCI
4.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.