CoChat

BAP1 Immunohistochemistry and p16 FISH to Separate Benign From Malignant Mesothelial Proliferations

Sheffield, Brandon S., Hwang, Harry C., Lee, Anna F., Thompson, Kim, Rodriguez, Stephanie, Tse, Christopher H., Gown, Allen M., Churg, Andrew · 2015 · American Journal of Surgical Pathology
Cited by 187

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

A variety of immunohistochemical (IHC) stains have been proposed to mark either benign or malignant mesothelial proliferations. Loss of the p16 tumor suppressor (CDKN2A), through homozygous deletions of 9p21, is a good marker of mesotheliomas but lacks sensitivity. Recent reports indicate that some mesotheliomas are associated with loss of BRCA-associated protein 1 (BAP1) expression. Here we investigate BAP1 and p16 as potential markers of malignancy and compare test characteristics with previously proposed markers using a well-characterized tissue microarray. BAP1 protein expression was interrogated by IHC. The p16 locus was examined by fluorescence in situ hybridization (FISH) directed toward chromosome 9p21. Loss of BAP1 was identified in 7/26 mesotheliomas and 0/49 benign proliferations. Loss of p16 was identified in 14/27 mesotheliomas and 0/40 benign proliferations, yielding 100% specificity and positive predictive value for each marker. Together, BAP1 IHC and p16 FISH were 58% sensitive for detecting malignancy. Various combinations of p53, EMA, IMP3, and GLUT1 showed reasonably high specificity (96% to 98%) but poor to extremely poor sensitivity. Combined BAP1 IHC/p16 FISH testing is a highly specific method of diagnosing malignant mesotheliomas when the question is whether a mesothelial proliferation is benign or malignant and is particularly useful when tissue invasion by mesothelial cells cannot be demonstrated. However, combined BAP1/p16 FISH testing is not highly sensitive, and negative results do not rule out a mesothelioma. The test characteristics of previously proposed markers EMA, p53, GLUT1, IMP3 suggest that, even in combination, these markers are not useful tools in this clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pas.0000000000000394

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 187

Metadata

Authors
Sheffield, B. S., Hwang, H. C., Lee, A. F., Thompson, K., Rodriguez, S., Tse, C. H., Gown, A. M., & Churg, A.
Venue
American Journal of Surgical Pathology
Published
2015-07
Volume
39
Issue
7
Pages
977-982
ISSN
0147-5185 (ISSN-L)
OpenAlex
W1982067611
Cited by
187
References
26
FWCI
15.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.