CoChat

Near-infrared spectroscopy as a hemodynamic monitor in critical illness

Ghanayem, Nancy S., Wernovsky, Gil, Hoffman, George M. · 2011 · Pediatric Critical Care Medicine
Cited by 141

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Near-infrared spectroscopy has moved from a research tool to a widely used clinical monitor in the critically ill pediatric patient over the last decade. The physiological and clinical evidence supporting this technology in practice is reviewed here. METHODOLOGY: A search of MEDLINE and PubMed was conducted to find validation studies, controlled trials, and other reports of near-infrared spectroscopy use in children and adults in the clinical setting. Guidelines published by the American Heart Association, the American Academy of Pediatrics, and the International Liaison Committee on Resuscitation were reviewed including further review of references cited. RESULTS: The biophysical properties of near-infrared spectroscopy devices allow measurement of capillary-venous oxyhemoglobin saturation in tissues a few centimeters beneath the surface sensor with validated accuracy in neonates, infants, and small patients. The biologic basis for the relationship of capillary-venous oxyhemoglobin saturation to cerebral injury has been described in animal and human studies. Normal ranges for cerebral and somatic capillary-venous oxyhemoglobin saturation have been described for normal newborns and infants and children with congenital heart disease and other disease states. The capillary-venous oxyhemoglobin saturation from both cerebral and somatic regions has been used to estimate mixed venous saturation and to predict biochemical shock, multiorgan dysfunction, and mortality in different populations. The relationship of cerebral capillary-venous oxyhemoglobin saturation to neuroimaging and functional assessment of outcome is limited but ongoing. Although there are numerous conflicting reports in small populations, expert opinion would suggest that special use may exist for near-infrared spectroscopy in patients with complex circulatory anatomy, with extremes of physiology, and in whom extended noninvasive monitoring is useful. CONCLUSIONS: Class II, level B evidence supports the conclusion that near-infrared spectroscopy offers a favorable risk-benefit profile and can be effective and beneficial as a hemodynamic monitor for the care of critically patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pcc.0b013e318221173a

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Ghanayem, N. S., Wernovsky, G., & Hoffman, G. M.
Venue
Pediatric Critical Care Medicine
Published
2011-07
Volume
12
Issue
4 Suppl
Pages
S27-S32
ISSN
1529-7535 (ISSN-L)
OpenAlex
W1979978875
Cited by
141
References
3
FWCI
6.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.