CoChat

Mass Screening for Fever in Children: A Comparison of 3 Infrared Thermal Detection Systems

Selent, Monica U., Molinari, NoelleAngelique M., Baxter, Amy, Nguyen, An V., Siegelson, Henry, Brown, Clive M., Plummer, Andrew, Higgins, Andrew, Podolsky, Susan, Spandorfer, Philip, Cohen, Nicole J., Fishbein, Daniel B. · 2013 · Pediatric Emergency Care
Cited by 39

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Infrared thermal detection systems (ITDSs) have been used with limited success outside the United States to screen for fever during recent outbreaks of novel infectious diseases. Although ITDSs are fairly accurate in detecting fever in adults, there is little information about their utility in children. METHODS: In a pediatric emergency department, we compared temperatures of children (<18 years old) measured using 3 ITDSs (OptoTherm Thermoscreen, FLIR ThermoVision 360, and Thermofocus 0800H3) to standard, age-appropriate temperature measurements (confirmed fever defined as ≥38.0°C [oral or rectal], ≥37.0°C [axillary]). Measured temperatures were compared with parental reports of fever using descriptive, multivariate, and receiver operating characteristic analyses. RESULTS: Of 855 patients, 400 (46.8%) had parent-reported fever, and 306 (35.8%) had confirmed fever. At optimal fever thresholds, OptoTherm and FLIR had sensitivity (83.0% and 83.7%, respectively) approximately equal to parental report (83.9%) and greater than Thermofocus (76.8%), and specificity (86.3% and 85.7%) greater than parental report (70.8%) and Thermofocus (79.4%). Correlation coefficients between traditional thermometry and ITDSs were 0.78 (OptoTherm), 0.75 (FLIR), and 0.66 (Thermofocus). CONCLUSIONS: Compared with traditional thermometry, FLIR and OptoTherm were reasonably accurate in detecting fever in children and better predictors of fever than parental report. These findings suggest that ITDSs could be a useful noninvasive screening tool for fever in the pediatric age group.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pec.0b013e3182854465

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Selent, M. U., Molinari, N. M., Baxter, A., Nguyen, A. V., Siegelson, H., Brown, C. M., Plummer, A., Higgins, A., Podolsky, S., Spandorfer, P., Cohen, N. J., & Fishbein, D. B.
Venue
Pediatric Emergency Care
Published
2013-03
Volume
29
Issue
3
Pages
305-313
ISSN
0749-5161 (ISSN-L)
OpenAlex
W2094474969
Cited by
39
References
1
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.