The DOI matches its Crossref record.
Foreign Body Granulomas after All Injectable Dermal Fillers: Part 1. Possible Causes
Open accessAbstract
Summary Genuine granuloma formation following implantation of injectable dermal fillers is a rare complication, with incidences ranging from one in 100 patients (1 percent) to one in 5000 (0.02 percent). Foreign body granulomas occur several months to years after injection at all implantation sites at the same time. Without treatment, they may grow to the size of beans, remain virtually unchanged for some years, and then resolve spontaneously. Three clinical and histologic types of foreign body granulomas can be distinguished: Cystic granulomas (synonyms: inflammatory, palisading, collagenolytic): these are caused mainly by injected biological gels such as collagens and hyaluronic acids. Their clinical signs are fluctuation (sterile abscess), extreme redness, and induration. Cystic granulomas are small and superficial, occur within the first year, and disappear spontaneously within another year. They are surrounded by a significant number of giant cells. Edematous granulomas (synonym: lipogranuloma): these are caused by artificial fluids such as silicone and polyacrylamides. They appear suddenly years after injection with extensive swelling and are surrounded and infiltrated by mononuclear and inflammatory cells. Sclerosing granulomas (synonyms: sarcoidal and xanthelasmic): these are caused by particulate injectables composed of polymethylmethacrylate, polylactic acid, poly-hydroxyethyl-methacrylate, calcium-hydroxylapatite, or dextran microspheres. Sclerosing granulomas occur generally 6 months to 3 years after implantation and are visible, often bluish confined nodules. Histologically, the implant is infiltrated by many macrophages and giant cells, fibroblasts, and collagen fibers but few inflammatory cells. Permanent implants are not characterized by a higher rate of foreign body granuloma per se than temporary implants; however, their clinical appearance is more pronounced and their persistence longer if not treated adequately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The host response to naturally-derived extracellular matrix biomaterials
Morris, A. H., Stamer, D. K., & Kyriakides, T. R. (2017) · Seminars in Immunology · doi:10.1016/j.smim.2017.01.002 · Cited by 180
Management of lip complications
Gupta, A., & Miller, P. J. (2019) · Facial Plastic Surgery Clinics of North America · doi:10.1016/j.fsc.2019.07.011 · Cited by 29
Metadata
- Authors
- Lemperle, G., Gauthier-Hazan, N., Wolters, M., Eisemann-Klein, M., Zimmermann, U., & Duffy, D. M.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2009-06
- Volume
- 123
- Issue
- 6
- Pages
- 1842-1863
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2020248296
- Cited by
- 265
- References
- 0
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Foreign Body Granulomas after All Injectable Dermal Fillers: Part 1. Possible Causes. https://app.cochat.ai/papers/10.1097/prs.0b013e31818236d7
- The paper
- Lemperle, G., Gauthier-Hazan, N., Wolters, M., Eisemann-Klein, M., Zimmermann, U., & Duffy, D. M. (2009). Foreign Body Granulomas after All Injectable Dermal Fillers: Part 1. Possible Causes. Plastic and Reconstructive Surgery. https://doi.org/10.1097/prs.0b013e31818236d7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.