CoChat

Biophysical Characteristics of Hyaluronic Acid Soft-Tissue Fillers and Their Relevance to Aesthetic Applications

Sundaram, Hema, Cassuto, Daniel · 2013 · Plastic and Reconstructive Surgery
Cited by 206

The DOI matches its Crossref record.

Abstract

BACKGROUND: The purpose of this study was to present new rheologic data for hyaluronic acid filler products, correlate them with recent tissue integration studies, and provide a scientific rationale for selecting appropriate products for volume replacement within different tissue levels and anatomical zones. A brief overview of the methodology of filler rheology studies and data analysis is provided. METHODS: Six U.S. Food and Drug Administration–approved, cross-linked, nonanimal-derived hyaluronic acid filler products and one hyaluronic acid product approved in Europe and elsewhere were studied: one cohesive polydensifiedmatrix hyaluronic acid (Belotero Balance, also known as Belotero Basic), two Hylacross hyaluronicacids (Juvéderm Ultra and Juvéderm Ultra Plus), one Vycross hyaluronic acid (Juvéderm Voluma), and three nonanimal stabilized hyaluronic acids (Perlane, Restylane and Restylane SubQ) [corrected].The elastic modulus, complex viscosity, and viscous modulus of each filler gel were quantified. Tan delta for each filler gel and also for calcium hydroxylapatite filler (Radiesse) was calculated at 0.7 Hz. RESULTS: Cohesive polydensified matrix hyaluronic acid (Belotero Balance) has the lowest elasticity and viscosity and the highest tan delta. This predicts its soft, flowing qualities and correlates with its homogeneous pattern of tissue integration after intradermal implantation. Nonanimal stabilized hyaluronic acid (Perlane and Restylane) has the highest elasticity and viscosity and low tan delta. This predicts its firm, less flowing qualities and correlates with a bolus-like pattern of tissue integration. Hylacross hyaluronic acid (Juvéderm) has intermediate elasticity, viscosity, and tan delta, correlating with its intermediate pattern of tissue integration. CONCLUSIONS: Rheologic evaluation reliably predicts tissue integration patterns and appropriate clinical applications of the studied fillers. Paradigms of layered filler placement can be designed to optimally address individual patient need.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/prs.0b013e31829d1d40

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Sundaram, H., & Cassuto, D.
Venue
Plastic and Reconstructive Surgery
Published
2013-10
Volume
132
Issue
4 Suppl 2
Pages
5S-21S
ISSN
0032-1052 (ISSN-L)
OpenAlex
W1988318745
Cited by
206
References
0
FWCI
12.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.