Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 681

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Nanofat Grafting: Basic Research and Clinical Applications

Tonnard, Patrick, Verpaele, Alexis, Peeters, Geert, Hamdi, Moustapha, Cornelissen, Maria, Declercq, Heidi·2013·Plastic and Reconstructive Surgery

Abstract

BACKGROUND: The indications for fat grafting are increasing steadily. In microfat grafting, thin injection cannulas are used. The authors describe their experience of fat injection with even thinner injection needles up to 27 gauge. The fat used for this purpose is processed into "nanofat." Clinical applications are described. Preliminary results of a study, set up to determine the cellular contents of nanofat, are presented. METHODS: Nanofat grafting was performed in 67 cases to correct superficial rhytides, scars, and dark lower eyelids. Three clinical cases are described. In the research study, three fat samples were analyzed. The first sample was a classic lipoaspirate (macrofat). The second sample was microfat, harvested with a multiport small-hole cannula. The third was microfat processed into nanofat. Processing consisted of emulsification and filtering of the lipoaspirate. Fat samples were analyzed for adipocyte viability. Cells from the stromal vascular fraction and the CD34+ subfraction were quantified. The stem cell quality was investigated by culturing the cells in standard and adipogenic media. RESULTS: No viable adipocytes were observed in the nanofat sample. Adipose-derived stem cells were still richly present in the nanofat sample. Cell cultures showed an equal proliferation and differentiation capacity of the stem cells from the three samples. Clinical applications showed remarkable improvements in skin quality 6 months postoperatively. No infections, fat cysts, granulomas, or other unwanted side effects were observed. CONCLUSIONS: Nanofat injections might become a new concept in the lipofilling area. In clinical situations, nanofat seems to be suitable for skin rejuvenation purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/prs.0b013e31829fe1b0

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Metadata

Authors
Tonnard, P., Verpaele, A., Peeters, G., Hamdi, M., Cornelissen, M., & Declercq, H.
Venue
Plastic and Reconstructive Surgery
Published
2013-10
Volume
132
Issue
4
Pages
1017-1026
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2058698833
Cited by
681
References
21
FWCI
16.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nanofat Grafting: Basic Research and Clinical Applications. https://app.cochat.ai/papers/10.1097/prs.0b013e31829fe1b0
The paper
Tonnard, P., Verpaele, A., Peeters, G., Hamdi, M., Cornelissen, M., & Declercq, H. (2013). Nanofat Grafting: Basic Research and Clinical Applications. Plastic and Reconstructive Surgery. https://doi.org/10.1097/prs.0b013e31829fe1b0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.