The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Cobicistat on Glomerular Filtration Rate in Subjects With Normal and Impaired Renal Function
Abstract
OBJECTIVE: This study evaluated the effect of cobicistat (COBI) on glomerular filtration rate in subjects with normal renal function (RF) or with mild/moderate renal impairment, by comparing creatinine clearance [estimated glomerular filtration rate (eGFR)] with actual GFR (aGFR) using iohexol, a probe drug excreted by glomerular filtration. COBI is a potent CYP3A inhibitor (pharmacoenhancer) currently in phase 3 testing with elvitegravir, atazanavir, and darunavir. METHODS: Normal RF subjects received COBI 150 mg QD, ritonavir (RTV) 100 mg QD, or placebo for 7 days; subjects with mild/moderate renal impairment received COBI 150 mg QD. The eGFR and aGFR were measured on days 0, 7, and 14 and within-subject changes calculated relative to day 0. COBI and RTV pharmacokinetics were analyzed on day 7. RESULTS: All 36 subjects in cohort 1 and 17 of 18 subjects in cohort 2 completed all study treatments. Study treatments were well tolerated. Small increases in serum creatinine with corresponding mean decreases in eGFR (∼10 mL/min or mL/min per 1.73 m) were observed on day 7 relative to day 0 in subjects receiving COBI (P < 0.05). The decreases were reversible on COBI discontinuation; mean eGFR values returned to baseline on day 14 (P > 0.05). No statistically significant changes in aGFR on days 7 or 14 relative to day 0 were seen with COBI (P > 0.05). No statistically significant decreases in aGFR or eGFR were observed with RTV or placebo. CONCLUSIONS: COBI affects eGFR but not the actual GFR. The time to onset, magnitude, and time to resolution of changes in eGFR are consistent with altered proximal tubular secretion of creatinine through inhibition of drug transporters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Cited by
Lucas, G. M., Ross, M. J., Stock, P. G., Shlipak, M. G., Wyatt, C. M., Gupta, S. K., Atta, M. G., Wools-Kaloustian, K. K., Pham, P. A., Bruggeman, L. A., et al. (2014) · Clinical Infectious Diseases · doi:10.1093/cid/ciu617 · Cited by 310
Mills, A., Arribas, J. R., Andrade-Villanueva, J., DiPerri, G., Van Lunzen, J., Koenig, E., Elion, R., Cavassini, M., Madruga, J. V., Brunetta, J., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(15)00348-5 · Cited by 302
Metadata
- Authors
- German, P., Liu, H. C., Szwarcberg, J., Hepner, M., Andrews, J., Kearney, B. P., & Mathias, A.
- Venue
- JAIDS Journal of Acquired Immune Deficiency Syndromes
- Published
- 2012-09-01
- Volume
- 61
- Issue
- 1
- Pages
- 32-40
- ISSN
- 1525-4135 (ISSN-L)
- OpenAlex
- W2017404902
- Cited by
- 164
- References
- 1
- FWCI
- 13.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Cobicistat on Glomerular Filtration Rate in Subjects With Normal and Impaired Renal Function. https://app.cochat.ai/papers/10.1097/qai.0b013e3182645648
- The paper
- German, P., Liu, H. C., Szwarcberg, J., Hepner, M., Andrews, J., Kearney, B. P., & Mathias, A. (2012). Effect of Cobicistat on Glomerular Filtration Rate in Subjects With Normal and Impaired Renal Function. JAIDS Journal of Acquired Immune Deficiency Syndromes. https://doi.org/10.1097/qai.0b013e3182645648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.