New diagnostic methods for tuberculosis
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: During the last decade, laboratory tests for the detection of Mycobacterium tuberculosis (Mtb) have improved dramatically. Improvements in the ability to detect latent infection with Mtb, disease associated with Mtb, and strains resistant to commonly used antibiotics are reviewed. RECENT FINDINGS: Advances in the detection of Mtb include light-emitting diode fluorescence microscopy, nucleic acid amplification of Mtb and drug-resistant strains, and more rapid liquid culture with adjunct drug susceptibility testing. In the detection of latent tuberculosis infection, interferon [gamma] release assays offer improved accuracy over the tuberculin skin test. SUMMARY: The past 10 years have seen the most rapid growth in new diagnostics for Mtb in over a century. Although these tests offer improvements in the ability to detect Mtb, drug-resistant isolates, and those with latent tuberculosis infection, these improvements are counter-balanced by the need to deploy these tests in areas where Mtb burden is highest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A systematic review of rapid diagnostic tests for the detection of tuberculosis infection
Dinnes, J., Deeks, J., Kunst, H., Gibson, A., Cummins, E., Waugh, N., Drobniewski, F., & Lalvani, A. (2007) · Health Technology Assessment · doi:10.3310/hta11030 · Cited by 666
Pai, M., Flores, L. L., Pai, N., Hubbard, A., Riley, L. W., & Colford, J. M. (2003) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(03)00772-2 · Cited by 384
Greco, S., Girardi, E., Navarra, A., & Saltini, C. (2006) · Thorax · doi:10.1136/thx.2005.054908 · Cited by 162
Cited by
Evaluation of the analytical performance of the Xpert MTB/RIF assay
Blakemore, R., Story, E., Helb, D., Kop, J., Banada, P., Owens, M. R., Chakravorty, S., Jones, M., & Alland, D. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00128-10 · Cited by 485
Al-Ateah, S. M., Al-Dowaidi, M. M., & El-Khizzi, N. A. (2012) · Saudi Medical Journal · doi:10.15537/1658-3175.5638 · Cited by 47
Evaluation for Granulomatous Inflammation on Fine Needle Aspiration Cytology Using Special Stains
Majeed, M. M., & Bukhari, M. H. (2011) · Pathology Research International · doi:10.4061/2011/851524 · Cited by 34
“They claimed at least 10% improvement in sensitivity and sensitivity if fluorescence microscopy is used as compared to direct smear examination [33, 34].”
Method
Metadata
- Authors
- Nyendak, M. R., Lewinsohn, D. A., & Lewinsohn, D. M.
- Venue
- Current Opinion in Infectious Diseases
- Published
- 2009-04
- Volume
- 22
- Issue
- 2
- Pages
- 174-182
- ISSN
- 0951-7375 (ISSN-L)
- OpenAlex
- W2005548728
- Cited by
- 94
- References
- 3
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.