The DOI matches its Crossref record.
Diffusion-Weighted Imaging With Apparent Diffusion Coefficient Mapping for Breast Cancer Detection as a Stand-Alone Parameter: Comparison With Dynamic Contrast-Enhanced and Multiparametric Magnetic Resonance Imaging
Open accessAbstract
Purpose: The aims of this study were to compare dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) with apparent diffusion coefficient mapping as a stand-alone parameter without any other supportive sequence for breast cancer detection and to assess its combination as multiparametric MRI (mpMRI) of the breast. Materials and Methods: In this institutional review board–approved single-center study, prospectively acquired data of 106 patients who underwent breast MRI from 12/2010 to 09/2014 for an imaging abnormality (Breast Imaging Reporting and Data System 0, 4/5) were retrospectively analyzed. Four readers independently assessed DWI and DCE as well as combined as mpMRI. Breast Imaging Reporting and Data System categories, lesion size, and mean apparent diffusion coefficient values were recorded. Histopathology was used as the gold standard. Appropriate statistical tests were used to compare diagnostic values. Results: There were 69 malignant and 41 benign tumors in 106 patients. Four patients presented with bilateral lesions. Dynamic contrast-enhanced MRI was the most sensitive test for breast cancer detection, with an average sensitivity of 100%. Diffusion-weighted imaging alone was less sensitive (82%; P < 0.001) but more specific than DCE-MRI (86.8% vs 76.6%; P = 0.002). Diagnostic accuracy was 83.7% for DWI and 90.6% for DCE-MRI. Multiparametric MRI achieved a sensitivity of 96.8%, not statistically different from DCE-MRI (P = 0.12) and with a similar specificity as DWI (83.8%; P = 0.195), maximizing diagnostic accuracy to 91.9%. There was almost perfect interreader agreement for DWI (κ = 0.864) and DCE-MRI (κ = 0.875) for differentiation of benign and malignant lesions. Conclusion: Dynamic contrast-enhanced MRI is most sensitive for breast cancer detection and thus still indispensable. Multiparametric MRI using DCE-MRI and DWI maintains a high sensitivity, increases specificity, and maximizes diagnostic accuracy, often preventing unnecessary breast biopsies. Diffusion-weighted imaging should not be used as a stand-alone parameter because it detects significantly fewer cancers in comparison with DCE-MRI and mpMRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
Self-citationContrast‐enhanced MRI for breast cancer screening
Mann, R. M., Kuhl, C. K., & Moy, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26654 · Cited by 356
Self-citationDalmiş, M. U., Gubern-Mérida, A., Vreemann, S., Bult, P., Karssemeijer, N., Mann, R., & Teuwen, J. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000544 · Cited by 120
Self-citation
Metadata
- Authors
- Pinker, K., Moy, L., Sutton, E. J., Mann, R. M., Weber, M., Thakur, S. B., Jochelson, M. S., Bago-Horvath, Z., Morris, E. A., Baltzer, P. A., & Helbich, T. H.
- Venue
- Investigative Radiology
- Published
- 2018-10
- Volume
- 53
- Issue
- 10
- Pages
- 587-595
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W2796198656
- Cited by
- 163
- References
- 0
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion-Weighted Imaging With Apparent Diffusion Coefficient Mapping for Breast Cancer Detection as a Stand-Alone Parameter: Comparison With Dynamic Contrast-Enhanced and Multiparametric Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1097/rli.0000000000000465
- The paper
- Pinker, K., Moy, L., Sutton, E. J., Mann, R. M., Weber, M., Thakur, S. B., Jochelson, M. S., Bago-Horvath, Z., Morris, E. A., Baltzer, P. A., & Helbich, T. H. (2018). Diffusion-Weighted Imaging With Apparent Diffusion Coefficient Mapping for Breast Cancer Detection as a Stand-Alone Parameter: Comparison With Dynamic Contrast-Enhanced and Multiparametric Magnetic Resonance Imaging. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000465
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.