The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Abstract
OBJECTIVES: Assessment of the complex stability and Gd3+ dissociation rate of all marketed gadolinium-based MRI contrast agents (GBCA) in human serum at pH 7.4 and 37 degrees C. METHODS AND RESULTS: The kinetic profiles of Gd3+ dissociation of GBCAs were determined by incubation for 15 days in human serum from healthy volunteers at a concentration of 1 mmol/L, pH 7.4, and 37 degrees C. The initial rates of Gd3+ release and the amounts of Gd3+ released after 15 days were established by HPLC-ICP-MS analysis. In an attempt to simulate the situation in patients with end-stage renal disease who often have elevated serum phosphate levels, the influence of 10 mmol/L phosphate on Gd3+ dissociation was also investigated.The GBCAs were grouped and ranked in the following order according to their stabilities in native human serum at pH 7.4 and 37 degrees C [% Gd release after 15 days and initial rate (%/d) (95% confidence interval) in brackets]. NONIONIC LINEAR GBCAS: Optimark [21 (19-22) %, 0.44 (0.40-0.51) %/d) and Omniscan [20 (17-20) %, 0.16 (0.15-0.17) %/d]. IONIC LINEAR GBCAS: Magnevist [1.9 (1.2-2.0) %, 0.16 (0.12-0.36) %/d], Multihance [1.9 (1.3-2.1) %, 0.18 (0.13-0.38) %/d], Vasovist [1.8 (1.4-1.9) %, 0.12 (0.11-0.18) %/d], and Primovist [1.1 (0.76-1.2) %, 0.07 (0.05-0.08) %/d]. MACROCYCLIC GBCAS: Gadovist, Prohance, and Dotarem (all < limit of quantification of 0.1%, <0.007%/d).In the presence of additional 10 mmol/L phosphate in serum, the initial Gd release rates of the nonionic linear GBCAs, Omniscan, and Optimark increased about 100-fold, and, after 15 days, the amount of Gd3+ released from these agents was more than 75% higher than in native serum. The initial rates found for the ionic linear GBCAs increased about 12- to 30-fold, but, despite this, increase in the initial rate, the amount of Gd3+ released after 15 days was comparable to that in native serum. The elevated phosphate level did not lead to any measurable release of Gd3+ from the 3 macrocyclic GBCAs. CONCLUSIONS: The release of Gd from all linear Gd3+ complexes in human serum was several orders of magnitude greater than predicted by the conditional stability constants. After 15 days, release of Gd3+ from the nonionic linear GBCAs was about 10 times higher than from the ionic linear GBCAs. Elevated serum phosphate levels accelerated the release of Gd3+ from nonionic linear GBCAs and, to a lesser degree, from the ionic linear GBCAs. All 3 macrocyclic GBCAs remained stable in human serum at both normal and elevated phosphate levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Self-citationMurata, N., Gonzalez-Cuyar, L. F., Murata, K., Fligner, C., Dills, R., Hippe, D., & Maravilla, K. R. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000252 · Cited by 408
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Metadata
- Authors
- Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J.
- Venue
- Investigative Radiology
- Published
- 2008-12
- Volume
- 43
- Issue
- 12
- Pages
- 817-828
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2060437861
- Cited by
- 539
- References
- 1
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C. https://app.cochat.ai/papers/10.1097/rli.0b013e3181852171
- The paper
- Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008). Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C. Investigative Radiology. https://doi.org/10.1097/rli.0b013e3181852171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.