CoChat

High Sensitivity: High-Resolution SPECT-CT/MR Molecular Imaging of Angiogenesis in the Vx2 Model

Open access
Lijowski, Michal, Caruthers, Shelton, Hu, Grace, Zhang, Huiying, Scott, Michael J., Williams, Todd, Erpelding, Todd, Schmieder, Anne H., Kiefer, Garry, Gulyas, Gyongyi, Athey, Phillip S., Gaffney, Patrick J., Wickline, Samuel A., Lanza, Gregory M. · 2009 · Investigative Radiology
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: The use of antiangiogenic therapy in conjunction with traditional chemotherapy is becoming increasingly in cancer management, but the optimal benefit of these targeted pharmaceuticals has been limited to a subset of the population treated. Improved imaging probes that permit sensitive detection and high-resolution characterization of tumor angiogenesis could improve patient risk-benefit stratification. The overarching objective of these experiments was to develop a dual modality alpha(nu)beta3-targeted nanoparticle molecular imaging agent that affords sensitive nuclear detection in conjunction with high-resolution MR characterization of tumor angiogenesis. MATERIALS AND METHODS: In part 1, New Zealand white rabbits (n = 21) bearing 14d Vx2 tumor received either alpha(nu)beta3-targeted 99mTc nanoparticles at doses of 11, 22, or 44 MBq/kg, nontargeted 99mTc nanoparticles at 22 MBq/kg, or alpha(nu)beta3-targeted 99mTc nanoparticles (22 MBq/kg) competitively inhibited with unlabeled alpha(nu)beta3-nanoparticles. All animals were imaged dynamically over 2 hours with a planar camera using a pinhole collimator. In part 2, the effectiveness of alpha(nu)beta3-targeted 99mTc nanoparticles in the Vx2 rabbit model was demonstrated using clinical SPECT-CT imaging techniques. Next, MR functionality was incorporated into alpha(nu)beta3-targeted 99mTc nanoparticles by inclusion of lipophilic gadolinium chelates into the outer phospholipid layer, and the concept of high sensitivity - high-resolution detection and characterization of tumor angiogenesis was shown using sequential SPECT-CT and MR molecular imaging with 3D neovascular mapping. RESULTS: alpha(nu)beta3-Targeted 99mTc nanoparticles at 22 MBq/kg produced the highest tumor-to-muscle contrast ratio (8.56 +/- 0.13, TMR) versus the 11 MBq/kg (7.32 +/- 0.12) and 44 MBq/kg (6.55 +/- 0.07) doses, (P < 0.05). TMR of nontargeted particles at 22.2 MBq/kg (5.48 +/- 0.09) was less (P < 0.05) than the equivalent dosage of alpha(nu)beta3-targeted 99mTc nanoparticles. Competitively inhibition of 99mTc alpha(nu)beta3-integrin-targeted nanoparticles at 22.2 MBq/kg reduced (P < 0.05) TMR (5.31 +/- 0.06) to the nontargeted control contrast level. Multislice CT imaging could not distinguish the presence of Vx2 tumor implanted in the popliteal fossa from lymph nodes in the same fossa or in the contralateral leg. However, the use of 99mTc alpha(nu)beta3-nanoparticles with SPECT-CT produced a clear neovasculature signal from the tumor that was absent in the nonimplanted hind leg. Using alpha(nu)beta3-targeted 99mTc-gadolinium nanoparticles, the sensitive detection of the Vx2 tumor was extended to allow MR molecular imaging and 3D mapping of angiogenesis in the small tumor, revealing an asymmetrically distributed, patchy neovasculature along the periphery of the cancer. CONCLUSION: Dual modality molecular imaging with alpha(nu)beta3-targeted 99mTc-gadolinium nanoparticles can afford highly sensitive and specific localization of tumor angiogenesis, which can be further characterized with high-resolution MR neovascular mapping, which may predict responsiveness to antiangiogenic therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0b013e31818935eb

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 79

Metadata

Authors
Lijowski, M., Caruthers, S., Hu, G., Zhang, H., Scott, M. J., Williams, T., Erpelding, T., Schmieder, A. H., Kiefer, G., Gulyas, G., Athey, P. S., Gaffney, P. J., Wickline, S. A., & Lanza, G. M.
Venue
Investigative Radiology
Published
2009-01
Volume
44
Issue
1
Pages
15-22
ISSN
0020-9996 (ISSN-L)
OpenAlex
W2046187833
Cited by
79
References
2
FWCI
6.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Sensitivity: High-Resolution SPECT-CT/MR Molecular Imaging of Angiogenesis in the Vx2 Model. https://app.cochat.ai/papers/10.1097/rli.0b013e31818935eb
The paper
Lijowski, M., Caruthers, S., Hu, G., Zhang, H., Scott, M. J., Williams, T., Erpelding, T., Schmieder, A. H., Kiefer, G., Gulyas, G., Athey, P. S., Gaffney, P. J., Wickline, S. A., & Lanza, G. M. (2009). High Sensitivity: High-Resolution SPECT-CT/MR Molecular Imaging of Angiogenesis in the Vx2 Model. Investigative Radiology. https://doi.org/10.1097/rli.0b013e31818935eb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.