Quantification of Perfusion and Permeability in Multiple Sclerosis: Dynamic Contrast-Enhanced MRI in 3D at 3T
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: The quantification of cerebral blood flow (CBF), cerebral blood volume (CBV), and blood-brain barrier permeability in scattered lesions in the brain is a methodological challenge. We aimed to investigate the feasibility of a 3D T1-weighted dynamic contrast-enhanced (DCE) MRI acquisition in combination with a 2-compartment modeling approach for the quantification of CBF, CBV and permeability surface area product (PS) in lesions, and normal-appearing white matter (NAWM) in patients with multiple sclerosis (MS). MATERIAL AND METHODS: In all, 19 MS patients (mean age 35 years, 12 female) underwent DCE-MRI with a 3D T1-weighted spoiled gradient-echo sequence on a 3T MRI scanner. A total of 44 slices (thickness 3 mm) with an in-plane resolution of 1.7 × 1.7 mm(2) (matrix size 128 × 104), providing coverage of the whole brain, were acquired every 2.1 seconds over a total measurement time of 420 s. Data postprocessing was performed using a set of 2-compartment models with automated model selection; CBF, CBV, and PS as a measure of blood-brain barrier leakage were determined in contrast-enhancing (CE) and nonenhancing lesions as well as in NAWM. RESULTS: Perfusion quantification produced reasonable values in lesions as well as in NAWM. In CE lesions, CBF (22.9 (22.7) vs. 15.8 (6.7) mL/100 mL/min), CBV (1.18 (0.48) vs. 0.76 (0.19) mL/100 mL), and PS (0.98 (0.46) vs. 0.04 (0.03) mL/100 mL/min) were significantly (P < 0.001) higher than in NAWM. In nonenhancing lesions, a weakly (P < 0.05) significantly increased CBV of 1.00 (0.35) mL/100 mL, compared with NAWM, was observed. CONCLUSION: Our study demonstrates the feasibility of 3D T1-weighted DCE-MRI for the quantitative assessment of CBF, CBV, and PS in NAWM as well as in multiple MS lesions scattered throughout the brain, even without previous knowledge of their location. Quantification on the region level produced reasonable values both in lesions and in NAWM, but parameter maps would benefit from an increase in contrast-to-noise ratio. The increased values of CBF, CBV, and PS in CE lesions may reflect inflammatory activity, the heterogeneity of parameter estimates suggests a potential for lesion characterization. NAWM appears hypoperfused, this is in accordance with previous studies, but requires validation with a control group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Law, M., Saindane, A. M., Ge, Y., Babb, J. S., Johnson, G., Mannon, L. J., Herbert, J., & Grossman, R. I. (2004) · Radiology · doi:10.1148/radiol.2313030996 · Cited by 242
Cited by
Blood–brain barrier breakdown in Alzheimer disease and other neurodegenerative disorders
Sweeney, M. D., Sagare, A. P., & Zlokovic, B. V. (2018) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.188 · Cited by 3,076
The role of brain vasculature in neurodegenerative disorders
Sweeney, M. D., Kisler, K., Montagne, A., Toga, A. W., & Zlokovic, B. V. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0234-x · Cited by 998
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Self-citation25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Heye, A. K., Culling, R. D., Valdés Hernández, M. D. C., Thrippleton, M. J., & Wardlaw, J. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.09.002 · Cited by 406
Metadata
- Authors
- Ingrisch, M., Sourbron, S., Morhard, D., Ertl-Wagner, B., Kümpfel, T., Hohlfeld, R., Reiser, M., & Glaser, C.
- Venue
- Investigative Radiology
- Published
- 2012-04
- Volume
- 47
- Issue
- 4
- Pages
- 252-258
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2007300440
- Cited by
- 107
- References
- 1
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of Perfusion and Permeability in Multiple Sclerosis: Dynamic Contrast-Enhanced MRI in 3D at 3T. https://app.cochat.ai/papers/10.1097/rli.0b013e31823bfc97
- The paper
- Ingrisch, M., Sourbron, S., Morhard, D., Ertl-Wagner, B., Kümpfel, T., Hohlfeld, R., Reiser, M., & Glaser, C. (2012). Quantification of Perfusion and Permeability in Multiple Sclerosis: Dynamic Contrast-Enhanced MRI in 3D at 3T. Investigative Radiology. https://doi.org/10.1097/rli.0b013e31823bfc97
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.