CoChat

Performance of Deep Learning Model in Detecting Operable Lung Cancer With Chest Radiographs

Cha, Min Jae, Chung, Myung Jin, Lee, Jeong Hyun, Lee, Kyung Soo · 2019 · Journal of Thoracic Imaging

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Purpose: The aim of this study was to evaluate the diagnostic performance of a trained deep convolutional neural network (DCNN) model for detecting operable lung cancer with chest radiographs (CXRs). Materials and Methods: The institutional review board approved this study. A deep learning model (DLM) based on DCNN was trained with 17,211 CXRs (5700 CT-confirmed lung nodules in 3500 CXRs and 13,711 normal CXRs), finally augmented to 600,000 images. For validation, a trained DLM was tested with 1483 CXRs with surgically resected lung cancer, marked and scored by 2 radiologists. Furthermore, diagnostic performances of DLM and 6 human observers were compared with 500 cases (200 visible T1 lung cancer on CXR and 300 normal CXRs) and analyzed using free-response receiver-operating characteristics curve (FROC) analysis. Results: The overall detection rate of DLM for resected lung cancers (27.2±14.6 mm) was a sensitivity of 76.8% (1139/1483) with a false positive per image (FPPI) of 0.3 and area under the FROC curve (AUC) of 0.732. In the comparison with human readers, DLM demonstrated a sensitivity of 86.5% at 0.1 FPPI and a sensitivity of 92% at 0.3 FPPI with AUC of 0.899 at an FPPI range of 0.03 to 0.44 for detecting visible T1 lung cancers, which were superior to the average of 6 human readers [mean sensitivity; 78% (range, 71.6% to 82.6%) at an FPPI of 0.1% and 85% (range, 80.2% to 89.2%) at an FPPI of 0.3, AUC of 0.819 (range, 0.754 to 0.862) at an FPPI of 0.03 to 0.44). Conclusions: A DLM has high diagnostic performance in detecting operable lung cancer with CXR, demonstrating a potential of playing a pivotal role for lung cancer screening.

Overview

Integrity signals

Registry

Crossref · 10.1097/rti.0000000000000388

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Cited by

See all 58

Metadata

Authors
Cha, M. J., Chung, M. J., Lee, J. H., & Lee, K. S.
Affiliations
Samsung Medical Center (KR)
Corresponding author
Chung, Myung Jin
Venue
Journal of Thoracic Imaging
Published
2019-03
Volume
34
Issue
2
Pages
86-91
ISSN
0883-5993 (ISSN-L)
OpenAlex
W2908899327
Cited by
56
References
23
Citations by year
2026: 4 · 2025: 6 · 2024: 8 · 2023: 7 · 2022: 6 · 2021: 12 · 2020: 10 · 2019: 3
FWCI
3.58
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Thoracic Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
Keywords
resectable lung cancer, chest radiograph, deep convolutional neural networks, lung nodule detection, lung cancer screening, computer-aided detection, diagnostic accuracy, human observer comparison
MeSH terms
Deep Learning, Humans, Image Interpretation, Computer-Assisted, Lung, Lung Neoplasms, Sensitivity and Specificity, Radiography, Thoracic, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Deep Learning Model in Detecting Operable Lung Cancer With Chest Radiographs. https://app.cochat.ai/papers/10.1097/rti.0000000000000388
The paper
Cha, M. J., Chung, M. J., Lee, J. H., & Lee, K. S. (2019). Performance of Deep Learning Model in Detecting Operable Lung Cancer With Chest Radiographs. Journal of Thoracic Imaging. https://doi.org/10.1097/rti.0000000000000388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.