The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ground-glass Opacity Nodules: Histopathology, Imaging Evaluation, and Clinical Implications
Abstract
Ground-glass opacity (GGO) nodules noted at thin-section computed tomography (CT) scan have been shown to have a histopathologic relationship with atypical adenomatous hyperplasia, bronchioloalveolar carcinoma (BAC, or adenocarcinoma in situ), and adenocarcinoma with a predominant BAC component (minimally invasive adenocarcinoma). Patients harboring GGO nodules of BAC or adenocarcinoma with a predominant BAC component demonstrate negative results for malignancy at positron emission tomography. In peripheral adenocarcinoma of a part-solid (mixed GGO and solid attenuation) nodular nature, both the degree of disappearance of GGO area, when the lung window is changed to a mediastinal window image at CT scanning, and the maximum standardized uptake value at positron emission tomography correlate well with histopathologic BAC and non-BAC ratios. However, a high non-BAC ratio appears to be the only independent prognosis-determining factor. Epidermal growth factor receptor mutations are positively correlated with the GGO ratio at a thin-section CT scan in lung adenocarcinomas. As patients with a GGO nodule of BAC or adenocarcinoma with a predominant BAC component have a good prognosis, a wedge resection is recommended as a treatment option, in preference to lobectomy. Even for multiple malignant pure GGO nodules, minimally invasive surgery (including multiple resections) with the preservation of lung volume and adequate imaging follow-up studies are the recommended diagnostic and therapeutic measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vesselle, H., Salskov, A., Turcotte, E., Wiens, L., Schmidt, R., Jordan, C. D., Vallières, E., & Wood, D. E. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e31818307a7 · Cited by 165
Cited by
Travis, W. D., Asamura, H., Bankier, A. A., Beasley, M. B., Detterbeck, F., Flieder, D. B., Goo, J. M., MacMahon, H., Naidich, D., Nicholson, A. G., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.03.025 · Cited by 722
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Lee, G., Lee, H. Y., Park, H., Schiebler, M. L., van Beek, E. J. R., Ohno, Y., Seo, J. B., & Leung, A. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.09.005 · Cited by 282
Self-citationNatural History of Pure Ground-Glass Opacity Lung Nodules Detected by Low-Dose CT Scan
Chang, B., Hwang, J. H., Choi, Y.-H., Chung, M. P., Kim, H., Kwon, O. J., Lee, H. Y., Lee, K. S., Shim, Y. M., Han, J., et al. (2013) · Chest · doi:10.1378/chest.11-2501 · Cited by 275
Self-citationPersistent Pure Ground-Glass Opacity Lung Nodules ≥ 10 mm in Diameter at CT Scan
Lim, H.-J., Ahn, S., Lee, K. S., Han, J., Shim, Y. M., Woo, S., Kim, J.-H., Yie, M., Lee, H. Y., & Yi, C. A. (2013) · Chest · doi:10.1378/chest.12-2987 · Cited by 254
Self-citation
Metadata
- Authors
- Lee, H. Y., & Lee, K. S.
- Venue
- Journal of Thoracic Imaging
- Published
- 2011-05
- Volume
- 26
- Issue
- 2
- Pages
- 106-118
- ISSN
- 0883-5993 (ISSN-L)
- OpenAlex
- W2323500768
- Cited by
- 162
- References
- 1
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.