The DOI matches its Crossref record.
Shear Wave Ultrasound Elastography of the Prostate: Initial Results
Abstract
PURPOSE: This prospective study was to evaluate shear wave elastography (SWE) in the detection of prostate cancer (PC). METHODS: Patients scheduled for a transrectal ultrasound (TRUS) biopsy of the prostate because of elevated prostate-specific antigen levels or abnormal digital rectal examination result underwent a standard TRUS and SWE. A second TRUS examination and sextant biopsy by a second physician blinded to SWE results was then performed. Pathologic result was reviewed, and sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were calculated. RESULTS: A total of 53 patients (318 sextants) participated in the study. Mean age was 64.2 years (range, 53-79 years). A total of 26 foci of PC were detected in 11 patients (20.7%). On the basis of the receiver operating characteristic curve, a value of 37 kPa was used as the cutoff between benign and malignant. This produced a sensitivity of 96.2% (25/26), a specificity of 96.2% (281/292), a PPV of 69.4% (25/36), and an NPV of 99.6% (281/282). Six (55%) of 11 false-positive samples were secondary to benign calcifications. The Young modulus of PC ranged from 30 to 110 kPa (mean [SD], 58.0 [20.7] kPa). At the patient level, if a cutoff of 40 kPa was used, all PCs would have been detected, and the positive biopsy rate would be 11 (50%) of 22 compared to 11 (20.8%) of 53 without SWE--a 140% increase in the positive biopsy rate. CONCLUSIONS: Shear wave elastography has a high sensitivity, specificity, PPV, and NPV for the detection of PC. With a high PPV, patients with elevated prostate-specific antigen levels or abnormal results in the digital rectal examination and negative SWE may not require biopsy. This could significantly reduce the negative biopsy rate in PC detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Săftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Barr, R. G., Cosgrove, D., Brock, M., Cantisani, V., Correas, J. M., Postema, A. W., Salomon, G., Tsutsumi, M., Xu, H.-X., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.020 · Cited by 259
Self-citationDeep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Metadata
- Authors
- Barr, R. G., Memo, R., & Schaub, C. R.
- Venue
- Ultrasound Quarterly
- Published
- 2012-03
- Volume
- 28
- Issue
- 1
- Pages
- 13-20
- ISSN
- 0894-8771 (ISSN-L)
- OpenAlex
- W2074595488
- Cited by
- 195
- References
- 0
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shear Wave Ultrasound Elastography of the Prostate: Initial Results. https://app.cochat.ai/papers/10.1097/ruq.0b013e318249f594
- The paper
- Barr, R. G., Memo, R., & Schaub, C. R. (2012). Shear Wave Ultrasound Elastography of the Prostate: Initial Results. Ultrasound Quarterly. https://doi.org/10.1097/ruq.0b013e318249f594
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.