Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 335

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning

Mascagni, Pietro, Vardazaryan, Armine, Alapatt, Deepak, Urade, Takeshi, Emre, Taha, Fiorillo, Claudio, Pessaux, Patrick, Mutter, Didier, Marescaux, Jacques, Costamagna, Guido, Dallemagne, Bernard, Padoy, Nicolas·2022·Annals of Surgery

Abstract

Objective: To develop a deep learning model to automatically segment hepatocystic anatomy and assess the criteria defining the critical view of safety (CVS) in laparoscopic cholecystectomy (LC). Background: Poor implementation and subjective interpretation of CVS contributes to the stable rates of bile duct injuries in LC. As CVS is assessed visually, this task can be automated by using computer vision, an area of artificial intelligence aimed at interpreting images. Methods: Still images from LC videos were annotated with CVS criteria and hepatocystic anatomy segmentation. A deep neural network comprising a segmentation model to highlight hepatocystic anatomy and a classification model to predict CVS criteria achievement was trained and tested using 5-fold cross validation. Intersection over union, average precision, and balanced accuracy were computed to evaluate the model performance versus the annotated ground truth. Results: A total of 2854 images from 201 LC videos were annotated and 402 images were further segmented. Mean intersection over union for segmentation was 66.6%. The model assessed the achievement of CVS criteria with a mean average precision and balanced accuracy of 71.9% and 71.4%, respectively. Conclusions: Deep learning algorithms can be trained to reliably segment hepatocystic anatomy and assess CVS criteria in still laparoscopic images. Surgical-technical partnerships should be encouraged to develop and evaluate deep learning models to improve surgical safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0000000000004351

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 335

Metadata

Authors
Mascagni, P., Vardazaryan, A., Alapatt, D., Urade, T., Emre, T., Fiorillo, C., Pessaux, P., Mutter, D., Marescaux, J., Costamagna, G., Dallemagne, B., & Padoy, N.
Venue
Annals of Surgery
Published
2020-11-16
Volume
275
Issue
5
Pages
955-961
ISSN
  • 0003-4932 (ISSN-L)
  • 1528-1140
OpenAlex
W3101712992
Cited by
335
References
25
FWCI
24.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning. https://app.cochat.ai/papers/10.1097/sla.0000000000004351
The paper
Mascagni, P., Vardazaryan, A., Alapatt, D., Urade, T., Emre, T., Fiorillo, C., Pessaux, P., Mutter, D., Marescaux, J., Costamagna, G., Dallemagne, B., & Padoy, N. (2022). Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning. Annals of Surgery. https://doi.org/10.1097/sla.0000000000004351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.