The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning
Abstract
Objective: To develop a deep learning model to automatically segment hepatocystic anatomy and assess the criteria defining the critical view of safety (CVS) in laparoscopic cholecystectomy (LC). Background: Poor implementation and subjective interpretation of CVS contributes to the stable rates of bile duct injuries in LC. As CVS is assessed visually, this task can be automated by using computer vision, an area of artificial intelligence aimed at interpreting images. Methods: Still images from LC videos were annotated with CVS criteria and hepatocystic anatomy segmentation. A deep neural network comprising a segmentation model to highlight hepatocystic anatomy and a classification model to predict CVS criteria achievement was trained and tested using 5-fold cross validation. Intersection over union, average precision, and balanced accuracy were computed to evaluate the model performance versus the annotated ground truth. Results: A total of 2854 images from 201 LC videos were annotated and 402 images were further segmented. Mean intersection over union for segmentation was 66.6%. The model assessed the achievement of CVS criteria with a mean average precision and balanced accuracy of 71.9% and 71.4%, respectively. Conclusions: Deep learning algorithms can be trained to reliably segment hepatocystic anatomy and assess CVS criteria in still laparoscopic images. Surgical-technical partnerships should be encouraged to develop and evaluate deep learning models to improve surgical safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
Encoder-Decoder with Atrous Separable Convolution for Semantic Image Segmentation
Chen, L.-C., Zhu, Y., Papandreou, G., Schroff, F., & Adam, H. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01234-2_49 · Cited by 20,054
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
The Pascal Visual Object Classes Challenge: A Retrospective
Everingham, M., Eslami, S. M. A., Van Gool, L., Williams, C. K. I., Winn, J., & Zisserman, A. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-014-0733-5 · Cited by 7,139
An analysis of the problem of biliary injury during laparoscopic cholecystectomy.
Berci, G., & Morgenstern, L. (1995) · PubMed · Cited by 1,634
Way, L. W., Stewart, L., Gantert, W., Liu, K., Lee, C. M., Whang, K., & Hunter, J. G. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000060680.92690.e9 · Cited by 795
Rationale and Use of the Critical View of Safety in Laparoscopic Cholecystectomy
Strasberg, S. M., & Brunt, M. L. (2010) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2010.02.053 · Cited by 611
Surgical data science for next-generation interventions
Maier-Hein, L., Vedula, S. S., Speidel, S., Navab, N., Kikinis, R., Park, A., Eisenmann, M., Feussner, H., Forestier, G., Giannarou, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0132-7 · Cited by 566
Self-citationTornqvist, B., Stromberg, C., Persson, G., & Nilsson, M. (2012) · BMJ · doi:10.1136/bmj.e6457 · Cited by 535
Wakabayashi, G., Iwashita, Y., Hibi, T., Takada, T., Strasberg, S. M., Asbun, H. J., Endo, I., Umezawa, A., Asai, K., Suzuki, K., et al. (2018) · Journal of Hepato-Biliary-Pancreatic Sciences · doi:10.1002/jhbp.517 · Cited by 521
Cited by
Computer vision in surgery: from potential to clinical value
Mascagni, P., Alapatt, D., Sestini, L., Altieri, M. S., Madani, A., Watanabe, Y., Alseidi, A., Redan, J. A., Alfieri, S., Costamagna, G., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00707-5 · Cited by 228
Self-citationNagaraj, M. B., Namazi, B., Sankaranarayanan, G., & Scott, D. J. (2023) · Surgical Endoscopy · doi:10.1007/s00464-022-09509-y · Cited by 40
Metadata
- Authors
- Mascagni, P., Vardazaryan, A., Alapatt, D., Urade, T., Emre, T., Fiorillo, C., Pessaux, P., Mutter, D., Marescaux, J., Costamagna, G., Dallemagne, B., & Padoy, N.
- Venue
- Annals of Surgery
- Published
- 2020-11-16
- Volume
- 275
- Issue
- 5
- Pages
- 955-961
- ISSN
- 0003-4932 (ISSN-L)
- 1528-1140
- OpenAlex
- W3101712992
- Cited by
- 335
- References
- 25
- FWCI
- 24.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning. https://app.cochat.ai/papers/10.1097/sla.0000000000004351
- The paper
- Mascagni, P., Vardazaryan, A., Alapatt, D., Urade, T., Emre, T., Fiorillo, C., Pessaux, P., Mutter, D., Marescaux, J., Costamagna, G., Dallemagne, B., & Padoy, N. (2022). Artificial Intelligence for Surgical Safety: Automatic Assessment of the Critical View of Safety in Laparoscopic Cholecystectomy Using Deep Learning. Annals of Surgery. https://doi.org/10.1097/sla.0000000000004351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.