CoChat

A Prospective, Multicenter Registry Study to Evaluate the Clinical Feasibility of Targeted Axillary Dissection (TAD) in Node-positive Breast Cancer Patients

Kuemmel, Sherko, Heil, Joerg, Rueland, Anna, Seiberling, Christine, Harrach, Hakima, Schindowski, Dorothea, Lubitz, Juliane, Hellerhoff, Karin, Ankel, Christine, Graßhoff, Sven-Thomas, Deuschle, Petra, Hanf, Volker, Belke, Kerstin, Dall, Peter, Dorn, Julia, Kaltenecker, Gabriele, Kuehn, Thorsten, Beckmann, Ulrike, Potenberg, Jochem, Blohmer, Jens-Uwe, Kostara, Athina, Breit, Elisabeth, Holtschmidt, Johannes, Traut, Eugen, Reinisch, Mattea · 2022 · Annals of Surgery
Cited by 181

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Objective: This study aimed to investigate the feasibility and accuracy of non-radioactive TLN biopsy and TAD in routine clinical practice. Background Data: TAD involves TLN biopsy (TLNB) and sentinel lymph node biopsy and was recently introduced as a new standard for less invasive axillary staging in BC patients undergoing neoadjuvant systemic therapy (NST); however, clinical evidence is limited. Methods: The SenTa study is a prospective registry study conducted at 50 centers. Patients with invasive BC who nderwent clip insertion into the most suspicious axillary lymph node were eligible. Axillary surgery was performed with or without sentinel lymph node biopsy, TLNB, and/or axillary lymph node dissection (ALND). Main endpoints were the detection rate and FNR of TLNB and TAD after NST. Results: Between 2017 and 2018, 548 consecutive BC patients underwent clip placement into biopsy-confirmed positive lymph nodes. After NST (n = 473), the clipped TLN was intraoperatively resected in 329 of 423 patients [77.8%, 95% confidence interval (CI): 74.0–82.0]. TAD was successful in 199 of 229 patients (detection rate: 86.9%, 95% CI: 81.8–91.0), the SLN and TLN were identical in 129 patient (64.8%). FNRs were 7.2% (8 of 111, 95% CI: 3.1–13.6) for TLNB followed by ALND (n = 203) and 4.3% (2 of 46, 95% CI: 0.5–14.8) for TAD followed by ALND (n = 77). Conclusions: The SenTa study demonstrates the feasibility of TAD in a real-world cohort of BC patients. Our findings are of great importance for de-escalation of surgical strategies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0000000000004572

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 181

Metadata

Authors
Kuemmel, S., Heil, J., Rueland, A., Seiberling, C., Harrach, H., Schindowski, D., Lubitz, J., Hellerhoff, K., Ankel, C., Graßhoff, S.-T., Deuschle, P., Hanf, V., Belke, K., Dall, P., Dorn, J., Kaltenecker, G., Kuehn, T., Beckmann, U., Potenberg, J., Blohmer, J.-U., Kostara, A., Breit, E., Holtschmidt, J., Traut, E., & Reinisch, M.
Venue
Annals of Surgery
Published
2020-11-04
Volume
276
Issue
5
Pages
e553-e562
ISSN
0003-4932 (ISSN-L)
OpenAlex
W3096479038
Cited by
181
References
30
FWCI
6.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.