OBJECTIVE: To evaluate the risks and benefits of using a circular stapler (CS) compared with the hand-sewn (HS) method for the esophagogastric anastomosis after esophageal resection. BACKGROUND DATA: Previous randomized controlled trials (RCTs) indicated that the use of a CS might prevent anastomotic leakage, whereas it was more likely to lead to anastomotic strictures. The relative efficacy of this intervention in comparison with the HS method has not been conclusively determined. METHODS: A systematic review and meta-analysis of all RCTs that compared HS versus mechanical anastomosis using a CS was conducted regarding the leakage, strictures, operative time, and mortality. The study protocol was established a priori according to the recommendations of the Cochrane Collaboration. RESULTS: Twelve RCTs were included with a total of 1407 patients. The use of a CS, compared with the HS method, (1) led to no significant difference in the incidence of anastomotic leakage [risk ratio (RR): 1.02, 95% confidence interval (CI): 0.66-1.59] or postoperative mortality (RR: 1.64, 95% CI: 0.95-2.83), (2) increased the incidence of anastomotic strictures (RR: 1.67, 95% CI: 1.16-2.42), and (3) reduced the length of the operation time (mean: -15.3 minutes, range: -28.1 to -2.39). For these results, a subgroup analysis and a meta-regression analysis yielded no significant differences for the anastomotic site, diameter of the CS, layer, or configuration. CONCLUSION: The use of a CS contributed to reducing the length of the operation, but was associated with an increased risk of anastomotic strictures. Both the CS and the HS method are viable alternatives in the reconstruction after esophagectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Law, S. Y.-K., Fok, M., Chu, K., & Wong, J. W. (1997) · Annals of Surgery · doi:10.1097/00000658-199708000-00008 · Cited by 235
Comparison of Stapled and Hand-sewn Esophagogastric Anastomoses
Beitler, A. L., & Urschel, J. D. (1998) · The American Journal of Surgery · doi:10.1016/s0002-9610(98)00002-6 · Cited by 123
Suturing or stapling in gastrointestinal surgery: A prospective randomized study
George, W. D. (1991) · Journal of British Surgery · doi:10.1002/bjs.1800780322 · Cited by 112
Nederlof, N., Tilanus, H. W., Tran, T. C. K., Hop, W., Wijnhoven, B., & de Jonge, J. (2011) · Annals of Surgery · doi:10.1097/sla.0b013e31822676a9 · Cited by 112 · cited 5×
“Previous reviews1,3,13 on this topic that did not include any analyses according to detailed surgical techniques suggested that there was an association between anastomotic leakages and strictures related to: (1) the diameters of the circular staplers,14 (2) the anastomotic configurations (end-to-end or end-to-side)2,…”
BackgroundMethodInfluentialUrschel, J. D., Blewett, C. J., Bennett, W. F., Miller, J. D., & Young, J. E. M. (2001) · Diseases of the Esophagus · doi:10.1046/j.1442-2050.2001.00187.x · Cited by 109
Anastomotic Complications Associated with Stapled Versus Hand-Sewn Anastomosis
Worrell, S., Mumtaz, S., Tsuboi, K., Lee, T. H., & Mittal, S. K. (2010) · Journal of Surgical Research · doi:10.1016/j.jss.2009.07.004 · Cited by 31
Cited by
Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage
Chadi, S. A., Fingerhut, A., Berho, M., DeMeester, S. R., Fleshman, J. W., Hyman, N. H., Margolin, D. A., Martz, J. E., McLemore, E. C., Molena, D., et al. (2016) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-016-3255-3 · Cited by 205
“colleagues found an increased rate of anastomotic stricture with circular-stapled anastomoses but no increase in AL rates.(40) Neutzling et al.”
Background
Metadata
- Authors
- Honda, M., Kuriyama, A., Noma, H., Nunobe, S., & Furukawa, T. A.
- Venue
- Annals of Surgery
- Published
- 2013-02
- Volume
- 257
- Issue
- 2
- Pages
- 238-248
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2323797057
- Cited by
- 163
- References
- 8
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hand-Sewn Versus Mechanical Esophagogastric Anastomosis After Esophagectomy: A Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1097/sla.0b013e31826d4723
- The paper
- Honda, M., Kuriyama, A., Noma, H., Nunobe, S., & Furukawa, T. A. (2013). Hand-Sewn Versus Mechanical Esophagogastric Anastomosis After Esophagectomy: A Systematic Review and Meta-Analysis. Annals of Surgery. https://doi.org/10.1097/sla.0b013e31826d4723
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.