CoChat

Incidence, Predictors, and Outcomes of Cardiac Pacing After Cardiac Transplantation: An 11-Year Retrospective Analysis

Woo, Gregory W., Schofield, Richard S., Pauly, Daniel F., Hill, James A., Conti, Jamie B., Kron, Jordana, Klodell, Charles T., Singh, Ramanjeet, Aranda, Juan M. · 2008 · Transplantation
Cited by 40

The DOI matches its Crossref record.

Abstract

More than 20% of cardiac transplant patients go on to require permanent pacing. We sought to determine the incidence of cardiac pacing in our cardiac transplant population and identify characteristics that may predict which patients will require permanent pacing. We reviewed medical records of cardiac transplant recipients and compared baseline characteristics of patients who received pacemakers with those of patients who did not receive pacemakers. Of 292 patients included in this analysis, 71 (24%) required permanent posttransplant pacing. Use of amiodarone before transplant was associated with a nonsignificant trend toward needing a pacemaker after transplant (P=0.08). Patients undergoing biatrial anastomosis were more likely to require permanent pacing than patients undergoing bicaval anastomosis (P<0.001). Approximately one fourth of cardiac transplant patients require permanent pacing. Surgical technique is a major predictor of who will require permanent pacing after cardiac transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/tp.0b013e31816b677c

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 17

  1. Montero, 1992, Pacing requirements after orthotopic heart transplantation: Incidence and related factors., J Heart Lung Transplant, 11, 799
  2. Herre, 2000, Cardiac pacemakers in the transplanted heart: Short term with the biatrial anastomosis and unnecessary with the bicaval anastomosis., Curr Opin Cardiol, 15, 115, 10.1097/00001573-200003000-00009 · doi:10.1097/00001573-200003000-00009
  3. Melton, 1999, Optimal cardiac pacing after heart transplantation., Pacing Clin Electrophysiol, 22, 1510, 10.1111/j.1540-8159.1999.tb00356.x · DOI · Paper page
  4. Alvarez, 1995, Electrophysiologic effects of procainamide, mexiletine, and amiodarone on the transplanted heart. Experimental study., J Thorac Cardiovasc Surg, 109, 899, 10.1016/S0022-5223(95)70314-4 · doi:10.1016/s0022-5223(95)70314-4
  5. Scott, 1991, Long-term pacing in heart transplant recipients is usually unnecessary., Pacing Clin Electrophysiol, 14, 1792, 10.1111/j.1540-8159.1991.tb02768.x · DOI
  6. Heinz, 1998, Benign prognosis of early sinus node dysfunction after orthotopic cardiac transplantation., Pacing Clin Electrophysiol, 21, 422, 10.1111/j.1540-8159.1998.tb00067.x · doi:10.1111/j.1540-8159.1998.tb00067.x
  7. Holt, 1996, Permanent pacemaker use after cardiac transplantation: Completing the audit cycle., Heart, 76, 435, 10.1136/hrt.76.5.435 · doi:10.1136/hrt.76.5.435
  8. Rothman, 1996, Eliminating bradyarrhythmias after orthotopic heart transplantation., Circulation, 94, II278
  9. Deleuze, 1995, Orthotopic cardiac transplantation with direct caval anastomosis: Is it the optimal procedure?, J Thorac Cardiovasc Surg, 109, 731, 10.1016/S0022-5223(95)70355-1 · doi:10.1016/s0022-5223(95)70355-1
  10. Milano, 2000, Evaluation of early postoperative results after bicaval versus standard cardiac transplantation and review of the literature., Am Heart J, 140, 717, 10.1067/mhj.2000.111105 · DOI
  11. Morgan, 2005, Orthotopic cardiac transplantation: Comparison of outcome using biatrial, bicaval, and total techniques., J Cardiac Surg, 20, 102, 10.1111/j.0886-0440.2005.05011.x · doi:10.1111/j.0886-0440.2005.05011.x
  12. Ellenbogen, 1990, Electrophysiological effects of adenosine in the transplanted human heart. Evidence of supersensitivity., Circulation, 81, 821, 10.1161/01.CIR.81.3.821 · DOI
  13. Bertolet, 1996, Bradycardia after heart transplantation: Reversal with theophylline., J Am Coll Cardiol, 28, 396, 10.1016/0735-1097(96)00162-3 · DOI
  14. Coons, 2004, Terbutaline for chronotropic support in heart transplantation., Ann Pharmacother, 38, 586, 10.1345/aph.1D440 · doi:10.1345/aph.1d440
  15. Raghavan, 1995, Long-term follow-up of heart transplant recipients requiring permanent pacemakers., J Heart Lung Transplant, 14, 1081
  16. Cataldo, 1996, Atrioventricular block occurring later after heart transplantation: Presentation of three cases and literature review., Pacing Clin Electrophysiol, 19, 325, 10.1111/j.1540-8159.1996.tb03334.x · DOI
  17. Heinz, 1992, Sinus node dysfunction after orthotopic cardiac transplantation: Postoperative incidence and long-term implications., Pacing Clin Electrophysiol, 15, 731, 10.1111/j.1540-8159.1992.tb06838.x · DOI · Paper page

Cited by

See all 40

Metadata

Authors
Woo, G. W., Schofield, R. S., Pauly, D. F., Hill, J. A., Conti, J. B., Kron, J., Klodell, C. T., Singh, R., & Aranda, J. M.
Venue
Transplantation
Published
2008-04-27
Volume
85
Issue
8
Pages
1216-1218
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2000628516
Cited by
40
References
0
FWCI
1.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence, Predictors, and Outcomes of Cardiac Pacing After Cardiac Transplantation: An 11-Year Retrospective Analysis. https://app.cochat.ai/papers/10.1097/tp.0b013e31816b677c
The paper
Woo, G. W., Schofield, R. S., Pauly, D. F., Hill, J. A., Conti, J. B., Kron, J., Klodell, C. T., Singh, R., & Aranda, J. M. (2008). Incidence, Predictors, and Outcomes of Cardiac Pacing After Cardiac Transplantation: An 11-Year Retrospective Analysis. Transplantation. https://doi.org/10.1097/tp.0b013e31816b677c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.