CoChat

Screening for New-Onset Diabetes After Kidney Transplantation: Limitations of Fasting Glucose and Advantages of Afternoon Glucose and Glycated Hemoglobin

Yates, Christopher J., Fourlanos, Spiros, Colman, Peter G., Cohney, Solomon J. · 2013 · Transplantation
Cited by 60

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The sensitivity of fasting plasma glucose (FPG) in screening for new-onset diabetes after transplantation (NODAT) has been questioned, particularly in the presence of moderate-dose prednisolone, where peak plasma glucose occurs 7 to 8 hr after administration. Oral glucose tolerance testing (OGTT) has been mooted as an alternative but is inconvenient for patients. METHODS: We compared sensitivity of screening tests for NODAT at 6 weeks, 3 months, and 12 months after kidney transplantation in recipients receiving prednisolone, mycophenolate, and tacrolimus. RESULTS: At 6 weeks, NODAT (capillary blood glucose [CapBG] ≥11.1 mmol/L, FPG ≥7.0 mmol/L, 2-hr plasma glucose ≥11.1 mmol/L, or glycated hemoglobin [HbA1c] ≥6.5%) was detected in 46% with CapBG versus 12% with OGTT (P=0.013), 4% with HbA1c (P<0.001), and 0% with FPG (P<0.001; n=26). At 3 months, NODAT was present in 14% with HbA1c versus 20% with OGTT (P=0.600) and 2% with FPG (P=0.059; n=50), whereas, at 12 months, NODAT was found in 4% with HbA1c versus 6% with OGTT (P=1.00) and 2% with FPG (P=0.618; n=51). Combining 3- and 12-month data, OGTT recorded NODAT in 14% and impaired glucose tolerance in 28%, whereas HbA1c detected NODAT in 10% and impaired glucose tolerance (from ≥5.7 to <6.5%) in 51%. Employing HbA1c as a screening test and reserving OGTT for those with impaired glucose tolerance would detect NODAT with a sensitivity more than 94%, avoiding the need for OGTT in 49% of patients. CONCLUSIONS: This study confirms the inadequacy of FPG screening for NODAT in the first 6 weeks after transplantation, at which time 4 p.m. CapBG also outperformed OGTT. From 3 months, HbA1c had similar sensitivity to OGTT and represents a convenient alternative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/tp.0b013e3182a012f3

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 60

Metadata

Authors
Yates, C. J., Fourlanos, S., Colman, P. G., & Cohney, S. J.
Venue
Transplantation
Published
2013-10-27
Volume
96
Issue
8
Pages
726-731
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2326337578
Cited by
60
References
4
FWCI
4.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.