The DOI matches its Crossref record.
Three-Dimensional Distribution of the Electric Field Induced in the Brain by Transcranial Magnetic Stimulation Using Figure-8 and Deep H-Coils
Abstract
The H-coils are a novel development in transcranial magnetic stimulation (TMS), designed to achieve effective stimulation of deep neuronal regions without inducing unbearable fields cortically, thus broadly expanding the potential feasibility of TMS for research and for treating various neurologic disorders. This study compared the field distribution of two H-coil versions, termed H1 and H2, and of a standard figure-of-eight coil. Three-dimensional electrical field distributions of the H1 and H2-coils, designed for effective stimulation of prefrontal regions, and of a standard figure-8 coil, were measured in a head model filled with physiologic saline solution. With stimulator output at 120% of the hand motor threshold, suprathreshold field is induced by the H1-coil at lateral and medial frontal regions at depths of up to 4 to 5 cm, and by the H2-coil at medial prefrontal regions up to 2 to 3 cm, and at lateral frontal regions up to 5 to 6 cm. The figure-8 coil induced suprathreshold field focally under the coil's central segment, at depths of up to 1.5 cm. The ability of the H-coils to stimulate effectively deeper neuronal structures is obtained at the cost of a wider electrical field distribution in the brain. However, the H-coils enable simultaneous stimulation of several brain regions, whereas the depth penetration in each region can be controlled either by adjusting the stimulator output, and/or by varying the distance between various coil elements and the skull.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
Lefaucheur, J.-P., André-Obadia, N., Antal, A., Ayache, S. S., Baeken, C., Benninger, D. H., Cantello, R. M., Cincotta, M., de Carvalho, M., De Ridder, D., et al. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.021 · Cited by 2,119
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Perera, T., George, M. S., Grammer, G., Janicak, P. G., Pascual-Leone, A., & Wirecki, T. S. (2016) · Brain Stimulation · doi:10.1016/j.brs.2016.03.010 · Cited by 674
Noninvasive brain stimulation: from physiology to network dynamics and back
Dayan, E., Censor, N., Buch, E. R., Sandrini, M., & Cohen, L. G. (2013) · Nature Neuroscience · doi:10.1038/nn.3422 · Cited by 585
Metadata
- Authors
- Roth, Y., Amir, A., Levkovitz, Y., & Zangen, A.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2007-02
- Volume
- 24
- Issue
- 1
- Pages
- 31-38
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2031572915
- Cited by
- 389
- References
- 0
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-Dimensional Distribution of the Electric Field Induced in the Brain by Transcranial Magnetic Stimulation Using Figure-8 and Deep H-Coils. https://app.cochat.ai/papers/10.1097/wnp.0b013e31802fa393
- The paper
- Roth, Y., Amir, A., Levkovitz, Y., & Zangen, A. (2007). Three-Dimensional Distribution of the Electric Field Induced in the Brain by Transcranial Magnetic Stimulation Using Figure-8 and Deep H-Coils. Journal of Clinical Neurophysiology. https://doi.org/10.1097/wnp.0b013e31802fa393
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.