Relative Ineffectiveness of Ultrabrief Right Unilateral Versus Bilateral Electroconvulsive Therapy in Depression
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Bilateral (BL) electrode placement delivered at 2.5 times the initial seizure threshold (ST; 2.5 x ST) is the gold standard method for seizure delivery during electroconvulsive therapy (ECT). However, there is a growing interest in using a high dose (6 x ST) with ultrabrief right unilateral (UB-RUL) electrode placement to reduce the incidence of possible short-term memory problems associated with BL ECT. Although studies have found UB-RUL ECT to have similar effectiveness to BL ECT, the objective of this study was to determine potential differences in efficiency (ie, the number of treatments needed to reach remission). METHODS: Electroconvulsive therapeutic data for 56 patients with depression treated during 2006 and 2007 were analyzed via retrospective chart review. A total of 26 patients were started on UB-RUL ECT, whereas 30 patients were started on brief pulse BL ECT. RESULTS: The patients started on high-dose UB-RUL ECT required significantly more treatments than the patients started on BL ECT (9.4 [3.3] vs 7.7 [2.8] treatments). Of the 26 patients started on UB-RUL ECT, 12 (46%) experienced a lack of effectiveness and/or insufficient seizure induction and were thus switched to BL ECT; the 8 patients switched because of lack of effectiveness received a mean (SD) of 12.2 (2.9) treatments, whereas the 4 patients switched because of insufficient seizure induction received a mean (SD) of 11.3 (3.6) treatments. CONCLUSIONS: These findings add to an emerging story of reduced efficiency of UB-RUL versus BL electrode placement for an index course of ECT for the treatment of depression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2003) · The Lancet · doi:10.1016/s0140-6736(03)12705-5 · Cited by 1,706
Sackeim, H. A., Haskett, R. F., Mulsant, B. H., Thase, M. E., Mann, J. J., Pettinati, H. M., Greenberg, R. M., Crowe, R. R., Cooper, T. B., & Prudic, J. (2001) · JAMA · doi:10.1001/jama.285.10.1299 · Cited by 686 · cited 1×
“8 treatments to remission.(16) Moreover, a recent comparison of UB (0.”
BackgroundPatients' perspectives on electroconvulsive therapy: systematic review
Rose, D., Fleischmann, P., Wykes, T., Leese, M., & Bindman, J. (2003) · BMJ · doi:10.1136/bmj.326.7403.1363 · Cited by 497
Kellner, C. H., Knapp, R. G., Petrides, G., Rummans, T. A., Husain, M. M., Rasmussen, K., Mueller, M., Bernstein, H. J., O’Connor, K., Smith, G., et al. (2006) · Archives of General Psychiatry · doi:10.1001/archpsyc.63.12.1337 · Cited by 471
A comparison of RUL ultrabrief pulse (0.3 ms) ECT and standard RUL ECT
Loo, C. K., Sainsbury, K., Sheehan, P., & Lyndon, B. (2008) · The International Journal of Neuropsychopharmacology · doi:10.1017/s1461145708009292 · Cited by 127
Cited by
Electroconvulsive Therapy Stimulus Parameters: Rethinking Dosage
Peterchev, A. V., Rosa, M. A., Deng, Z.-D., Prudic, J., & Lisanby, S. H. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48165 · Cited by 213
Electrode Placement in Electroconvulsive Therapy (ECT): A Review of the Literature
Kellner, C. H., Tobias, K. G., & Wiegand, J. (2010) · The Journal of ECT · doi:10.1097/yct.0b013e3181e48154 · Cited by 88
Electroconvulsive Therapy in Geriatric Psychiatry
Meyer, J. P., Swetter, S. K., & Kellner, C. H. (2018) · Psychiatric Clinics of North America · doi:10.1016/j.psc.2017.10.007 · Cited by 27
Metadata
- Authors
- McCormick, L. M., Brumm, M. C., Benede, A. K., & Lewis, J. L.
- Venue
- The Journal of ECT
- Published
- 2009-12
- Volume
- 25
- Issue
- 4
- Pages
- 238-242
- ISSN
- 1095-0680 (ISSN-L)
- OpenAlex
- W1985958726
- Cited by
- 38
- References
- 5
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.