Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 111

The DOI matches its Crossref record.

Mechanical properties and in vitro characterization of polyvinyl alcohol-nano-silver hydrogel wound dressings

Oliveira, R. N., Rouzé, R., Quilty, B., Alves, G. G., Soares, G. D. A., Thiré, R. M. S. M., McGuinness, G. B. · 2014 · Interface Focus

Abstract

Polyvinyl alcohol (PVA) hydrogels are materials for potential use in burn healing. Silver nanoparticles can be synthesized within PVA hydrogels giving antimicrobial hydrogels. Hydrogels have to be swollen prior to their application, and the common medium available for that in hospitals is saline solution, but the hydrogel could also take up some of the wound's fluid. This work developed gamma-irradiated PVA/nano-Ag hydrogels for potential use in burn dressing applications. Silver nitrate (AgNO 3 ) was used as nano-Ag precursor agent. Saline solution, phosphate-buffered solution (PBS) pH 7.4 and solution pH 4.0 were used as swelling media. Microstructural evaluation revealed an effect of the nanoparticles on PVA crystallization. The swelling of the PVA-Ag samples in solution pH 4.0 was low, as was their silver delivery, compared with the equivalent samples swollen in the other media. The highest swelling and silver delivery were related to samples prepared with 0.50% AgNO 3 , and they also presented lower strength in PBS pH 7.4 and solution pH 4.0. Both PVA-Ag samples were also non-toxic and presented antimicrobial activity, confirming that 0.25% AgNO 3 concentration is sufficient to establish an antimicrobial effect. Both PVA-Ag samples presented suitable mechanical and swelling properties in all media, representative of potential burn site conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rsfs.2013.0049

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. 10.4103/0970-0358.70712 · DOI · Paper page
  2. 10.12968/jowc.2004.13.6.26625 · doi:10.12968/jowc.2004.13.6.26625
  3. Jewo PI, 2009, A comparative study of the wound healing properties of moist exposed burn ointment (MEBO) and silver sulphadiazine, Ann. Burns Fire Disasters, 22, 79
  4. 10.1016/j.ijpharm.2006.01.027 · DOI · Paper page
  5. 10.1016/S1361-3111(05)80001-9 · DOI · Paper page
  6. Gay MH, 1987, Antimicrobial wound dressings.
  7. 10.1016/j.matchemphys.2009.07.063 · DOI
  8. 10.1016/j.carbpol.2012.04.033 · DOI · Paper page
  9. 10.1007/3-540-46414-X_2 · DOI · Paper page
  10. 10.1016/S0032-3861(00)00031-8 · doi:10.1016/s0032-3861(00)00031-8
  11. 10.1007/s10967-010-0618-1 · doi:10.1007/s10967-010-0618-1
  12. 10.1016/j.polymdegradstab.2009.11.017 · doi:10.1016/j.polymdegradstab.2009.11.017
  13. 10.1016/j.msec.2012.05.016 · doi:10.1016/j.msec.2012.05.016
  14. 10.1016/j.colsurfb.2011.02.012 · doi:10.1016/j.colsurfb.2011.02.012
  15. 10.1016/j.biotechadv.2008.09.002 · DOI · Paper page
  16. 10.1016/S0305-4179(98)00009-6 · DOI · Paper page
  17. 10.1016/j.addr.2013.07.011 · DOI · Paper page
  18. 10.1016/j.matchemphys.2005.02.029 · doi:10.1016/j.matchemphys.2005.02.029
  19. 10.1016/j.synthmet.2006.11.009 · doi:10.1016/j.synthmet.2006.11.009
  20. 10.1016/j.radphyschem.2004.06.006 · doi:10.1016/j.radphyschem.2004.06.006
  21. 10.1016/j.carbpol.2012.07.005 · doi:10.1016/j.carbpol.2012.07.005
  22. 10.1016/j.biomaterials.2003.10.078 · DOI · Paper page
  23. 10.1016/j.saa.2012.03.085 · DOI
  24. 10.1016/j.eurpolymj.2007.03.023 · doi:10.1016/j.eurpolymj.2007.03.023
  25. 10.1007/s10965-013-0177-6 · DOI
  26. 10.1016/j.carbpol.2008.11.015 · DOI · Paper page
  27. 10.1016/S0142-9418(98)00049-X · doi:10.1016/s0142-9418(98)00049-x
  28. 10.1016/S0144-8617(03)00167-X · DOI
  29. 10.1007/s11051-010-9900-y · DOI · Paper page
  30. 10.1016/j.jmbbm.2012.01.021 · DOI
  31. 10.1016/j.colsurfb.2012.09.032 · DOI
  32. 10.1007/978-1-4419-5919-5 · DOI · Paper page
  33. Omer MAA, 2011, Gamma radiation synthesis and characterization of polyvinyl alcohol/silver nano composites film, J. Sci. Technol., 12, 104
  34. 10.1054/bjps.1999.3246 · doi:10.1054/bjps.1999.3246
  35. 10.1016/j.radphyschem.2012.02.005 · doi:10.1016/j.radphyschem.2012.02.005

Cited by

Metadata

Authors
Oliveira, R. N., Rouzé, R., Quilty, B., Alves, G. G., Soares, G. D. A., Thiré, R. M. S. M., & McGuinness, G. B.
Affiliations
  • Bioengineering Lab, Materials and Metallurgical Engineering Department, Health Science Centre, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
  • School of Biotechnology, Dublin City University, Dublin, Ireland
  • Department of Cell and Molecular Biology, Institute of Biology, Fluminense Federal University, Niteroi, RJ, Brazil
  • Institute of Biomedical Sciences, Health Science Centre, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
  • Centre for Medical Engineering Research, School of Mechanical and Manufacturing Engineering, Dublin City University, Dublin, Ireland
Venue
Interface Focus
Published
2014-02-06
Volume
4
Issue
1
Pages
20130049
ISSN
  • 2042-8898
  • 2042-8901
Cited by
111
References
0
Language
en
Licence
royalsociety.org/journals/ethics-policies/data-sharing-mining/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.