The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A multiscale model of thrombus development
Open accessAbstract
A two-dimensional multiscale model is introduced for studying formation of a thrombus (clot) in a blood vessel. It involves components for modelling viscous, incompressible blood plasma; non-activated and activated platelets; blood cells; activating chemicals; fibrinogen; and vessel walls and their interactions. The macroscale dynamics of the blood flow is described by the continuum Navier–Stokes equations. The microscale interactions between the activated platelets, the platelets and fibrinogen and the platelets and vessel wall are described through an extended stochastic discrete cellular Potts model. The model is tested for robustness with respect to fluctuations of basic parameters. Simulation results demonstrate the development of an inhomogeneous internal structure of the thrombus, which is confirmed by the preliminary experimental data. We also make predictions about different stages in thrombus development, which can be tested experimentally and suggest specific experiments. Lastly, we demonstrate that the dependence of the thrombus size on the blood flow rate in simulations is close to the one observed experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulation of biological cell sorting using a two-dimensional extended Potts model
Graner, F., & Glazier, J. A. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.2013 · Cited by 1,377
Cited by
Physics-informed neural networks (PINNs) for fluid mechanics: a review
Cai, S., Mao, Z., Wang, Z., Yin, M., & Karniadakis, G. E. (2021) · Acta Mechanica Sinica · doi:10.1007/s10409-021-01148-1 · Cited by 2,084
Procoagulant Activity in Hemostasis and Thrombosis: Virchow's Triad Revisited
Wolberg, A. S., Aleman, M. M., Leiderman, K., & Machlus, K. R. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31823a088c · Cited by 312
Fluid Mechanics of Blood Clot Formation
Fogelson, A. L., & Neeves, K. B. (2015) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010814-014513 · Cited by 302
The use of computational fluid dynamics in the development of ventricular assist devices
Fraser, K. H., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.10.014 · Cited by 278
Multi-scale modelling and simulation in systems biology
Dada, J. O., & Mendes, P. (2011) · Integrative Biology · doi:10.1039/c0ib00075b · Cited by 213
Metadata
- Authors
- Xu, Z., Chen, N., Kamocka, M. M., Rosen, E. D., & Alber, M.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2007-10-09
- Volume
- 5
- Issue
- 24
- Pages
- 705-722
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2104849069
- Cited by
- 192
- References
- 1
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multiscale model of thrombus development. https://app.cochat.ai/papers/10.1098/rsif.2007.1202
- The paper
- Xu, Z., Chen, N., Kamocka, M. M., Rosen, E. D., & Alber, M. (2008). A multiscale model of thrombus development. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2007.1202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.