The DOI matches its Crossref record.
Interconnected porous hydroxyapatite ceramics for bone tissue engineering
Open accessAbstract
Several porous calcium hydroxyapatite (HA) ceramics have been used clinically as bone substitutes, but most of them possessed few interpore connections, resulting in pathological fracture probably due to poor bone formation within the substitute. We recently developed a fully interconnected porous HA ceramic (IP-CHA) by adopting the ‘foam-gel’ technique. The IP-CHA had a three-dimensional structure with spherical pores of uniform size (average 150 μm, porosity 75%), which were interconnected by window-like holes (average diameter 40 μm), and also demonstrated adequate compression strength (10–12 MPa). In animal experiments, the IP-CHA showed superior osteoconduction, with the majority of pores filled with newly formed bone. The interconnected porous structure facilitates bone tissue engineering by allowing the introduction of mesenchymal cells, osteotropic agents such as bone morphogenetic protein or vasculature into the pores. Clinically, we have applied the IP-CHA to treat various bony defects in orthopaedic surgery, and radiographic examinations demonstrated that grafted IP-CHA gained radiopacity more quickly than the synthetic HA in clinical use previously. We review the accumulated data on bone tissue engineering using the novel scaffold and on clinical application in the orthopaedic field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone tissue engineering using 3D printing
Bose, S., Vahabzadeh, S., & Bandyopadhyay, A. (2013) · Materials Today · doi:10.1016/j.mattod.2013.11.017 · Cited by 1,866
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
Minimal surface scaffold designs for tissue engineering
Kapfer, S. C., Hyde, S. T., Mecke, K., Arns, C. H., & Schröder-Turk, G. E. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.012 · Cited by 579
Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings
Zhang, B., Myers, D., Wallace, G., Brandt, M., & Choong, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711878 · Cited by 394
Metadata
- Authors
- Yoshikawa, H., Tamai, N., Murase, T., & Myoui, A.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2008-12-23
- Volume
- 6
- Issue
- suppl_3
- Pages
- S341-8
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2096806264
- Cited by
- 203
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interconnected porous hydroxyapatite ceramics for bone tissue engineering. https://app.cochat.ai/papers/10.1098/rsif.2008.0425.focus
- The paper
- Yoshikawa, H., Tamai, N., Murase, T., & Myoui, A. (2009). Interconnected porous hydroxyapatite ceramics for bone tissue engineering. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2008.0425.focus
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.