The crystal structure of polyethylene terephthalate
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The crystal structure of polyethylene terephthalate (Terylene) has been determined by the interpretation of the X-ray diffraction patterns given by drawn fibres. The unit cell, which contains one chemical unit, —CO.C6H4.CO.O.(CH2)2O—, is triclinic, with a = 4.56Å, b = 5.94 Å, c = 10.75 Å, α = 98 1/2°, β = 118°, γ = 112°. This gives the density of the crystals as 1.455 g/cm3. If it is assumed that the density of amorphous regions in partly crystalline material is the same as that of the entirely amorphous material (1.335), the proportion by weight of crystals in ordinary drawn yarn (density 1.39) is 48%, and in specimens of the highest recorded density (1.41) it is 64.5%. These figures are, however, lower limits; if, as is likely, the density of amorphous regions in partly crystalline specimens is lower than 1.335, the proportions of crystalline material are higher than the figures given. The positions of atoms in the crystals have been deduced from the relative intensities of X-ray diffractions; approximate positions were found by trial-and-error methods, and refinement was then effected by calculations of electron densities, using the three-dimensional Fourier synthesis method. The molecules are nearly planar in configuration. Distances between atoms in neighbouring molecules are all normal Van der Waals contact distances; there is therefore no structural evidence for any unusually strong forces between the molecules. This conclusion is in agreement with that based on an estimate of the cohesion energy, which is very nearly the same as that of a comparable aliphatic polyester, polyethylene adipate. The high melting-point of polyethylene terephthalate in comparison with aliphatic polyesters is therefore not due to strong forces between the molecules; it is attributed to the O— ∕ rigidity of the aromatic ring with its attached —C groups. ∖∖ O In most drawn fibres of this polymer, the crystals do not have their c-axes (those parallel to the chain molecules) exactly parallel to the fibre axes; they are tilted in a precisely defined crystallographic direction, such that the 530 plane remains vertical and the inclination of the 001 plane to the fibre axis increases. This is especially well defined in fibres heated to 210° C and allowed to relax, the tilt angle being then about 5°. In principle it is expected that polymer crystals of triclinic symmetry would be tilted, but it is not clear what determines the crystallographic direction of tilt. Tilted crystal X-ray diffraction photographs played an important part in the structure determination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The X-ray measurement of the amorphous content of polythene samples
Matthews, J. L., Peiser, H. S., & Richards, R. B. (1949) · Acta Crystallographica · doi:10.1107/s0365110x49000199 · Cited by 183
An X-Ray Study of Some Linear Polyesters
Fuller, C. S., & Erickson, C. (1937) · Journal of the American Chemical Society · doi:10.1021/ja01281a037 · Cited by 94
Cited by
Nanometre diameter fibres of polymer, produced by electrospinning
Reneker, D. H., & Chun, I. (1996) · Nanotechnology · doi:10.1088/0957-4484/7/3/009 · Cited by 3,520
Infrared spectra of high polymers
Krimm, S. (2006) · Advances in Polymer Science · doi:10.1007/bfb0050351 · Cited by 621
Strength and toughness of crystalline polymer systems
Galeski, A. (2003) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2003.09.003 · Cited by 614
Solution of Gases in Polyethylene Terephthalate
Michaels, A. S., Vieth, W. R., & Barrie, J. A. (1963) · Journal of Applied Physics · doi:10.1063/1.1729066 · Cited by 463
Isothermal crystallization kinetics and melting behaviour of poly(ethylene terephthalate)
Lu, X. F., & Hay, J. N. (2001) · Polymer · doi:10.1016/s0032-3861(01)00502-x · Cited by 357
An Introduction to Polymer Physics
Bower, D. I., & Solis, F. J. (2003) · American Journal of Physics · doi:10.1119/1.1533063 · Cited by 333
Sakurada, I., & Kaji, K. (1970) · Journal of Polymer Science Part C: Polymer Symposia · doi:10.1002/polc.5070310108 · Cited by 180
Inside PEF: Chain Conformation and Dynamics in Crystalline and Amorphous Domains
Araujo, C. F., Nolasco, M. M., Ribeiro-Claro, P. J. A., Rudić, S., Silvestre, A. J. D., Vaz, P. D., & Sousa, A. F. (2018) · Macromolecules · doi:10.1021/acs.macromol.8b00192 · Cited by 168
Thermal conductivity of oriented crystalline polymers
Choy, C. L., Chen, F. C., & Luk, W. H. (1980) · Journal of Polymer Science: Polymer Physics Edition · doi:10.1002/pol.1980.180180603 · Cited by 132
(1980) · doi:10.1016/b978-0-08-092664-3.50007-9 · Cited by 16
Revisiting stress-oscillation in cold drawing of poly(ethylene terephthalate)
Heeley, E. L., Smith, J., Wan, C., Huband, S., Brambley, E., & Hughes, D. J. (2023) · Polymer · doi:10.1016/j.polymer.2023.126364 · Cited by 5
Crystalline Morphology of Homopolymers and Block Copolymers
Nojima, S., & Marubayashi, H. (2016) · Polymer Morphology · doi:10.1002/9781118892756.ch10 · Cited by 3
Metadata
- Authors
- Daubeny, R. D. P., Bunn, C. W., & Brown, C. J.
- Venue
- Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences
- Publisher
- The Royal Society
- Published
- 1954-12-07
- Volume
- 226
- Issue
- 1167
- Pages
- 531-542
- ISSN
- 0080-4630 (ISSN-L)
- 2053-9169
- OpenAlex
- W2025139684
- Cited by
- 626
- References
- 2
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.