The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An X-ray photoelectron spectroscopic study of the interaction of oxygen and nitric oxide with aluminium
Abstract
The interaction of oxygen and nitric oxide with clean aluminium surfaces has been investigated by X-ray photoelectron spectroscopy. Studies have been in the main confined to the temperature range 80–290 K and pressure range 10-6–10-2 Pa. The Al(2p) level is shown to exhibit a shifted component at a binding energy of ~ 74.5 eV after oxygen interaction at 80 K. A curve-fitting and deconvolution analysis of the shifted peak indicates that it is made up of two components, one at a binding energy of 74.0 eV and the other at 75.3 eV. The lower binding energy component (designated α) develops preferentially at 80 K while the higher binding energy one (β), assigned to Al2O3, is dominant at 290 K. We suggest that α is an incorporated oxygen structure which is a precursor to the formation of Al2O3. The initial sticking probability of oxygen at 80 K is 0.07 while at 290 K it is 0.02. The plasmon-loss features associated with the Al(2s) peak are shown to be sensitive to oxygen adsorption and therefore useful in confirming the surface monolayer. At 290 K and an oxygen pressure of 104 Pa the oxide thickness is estimated to be about 0.9 nm. When NO was adsorbed at 80 K three distinct N(1s) peaks were observed at binding energies of about 397, 403 and 407 eV. We assign the 397 eV peak to Nδ-ads arising from dissociation of the molecule and the two higher binding energy peaks to Nδ-ads and N2Oads. The N(1s) peak characteristic of NOδ-ads is close to the lower binding energy peak of the two N(1s) peaks associated with N2Oads while the O(1s) of NOδ-ads overlaps with the O(1s) peak of the surface oxide at a binding energy of about 532 eV. Mass spectroscopic analysis of the gas phase indicated that on warming to 85 K, the adlayer formed at 80 K, N2O was desorbed, confirming our assignment of the core-level spectra. The NOδ- and N2O species are not observed at 290 K while at 80 K exposure of the adlayer to water vapour results in the complete removal of weakly adsorbed N2O. By monitoring the intensities of the Al(2p), N(1s) and O(1s) peaks, estimates were made of the absolute and relative concentrations of the various species and various molecular processes delineated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Payne, B. P., Biesinger, M. C., & McIntyre, N. S. (2012) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2012.06.008 · Cited by 308
Metadata
- Authors
- Carley, A. F., & Roberts, M. W.
- Venue
- Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences
- Publisher
- The Royal Society
- Published
- 1978-11-22
- Volume
- 363
- Issue
- 1714
- Pages
- 403-424
- ISSN
- 0080-4630 (ISSN-L)
- 2053-9169
- OpenAlex
- W2000767451
- Cited by
- 187
- References
- 1
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An X-ray photoelectron spectroscopic study of the interaction of oxygen and nitric oxide with aluminium. https://app.cochat.ai/papers/10.1098/rspa.1978.0175
- The paper
- Carley, A. F., & Roberts, M. W. (1978). An X-ray photoelectron spectroscopic study of the interaction of oxygen and nitric oxide with aluminium. Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences. https://doi.org/10.1098/rspa.1978.0175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.