The DOI matches its Crossref record.
Flow behaviour of erythrocytes - I. Rotation and deformation in dilute suspensions
Abstract
The behaviour of individual human red cells and rouleaux were studied under the microscope in suspensions of < 2% haematocrit: (i) in Poiseuille flow by tracking the particles in glass tubes, and (ii) in Couette flow by observing cells in the stationary layer between counter-rotating glass disks. At shear stresses ≪ 0.1 N m-2, the rotations of red cells in plasma were in accord with theory applicable to rigid disks. At shear stresses > 0.1 N m-2, especially in viscous isotonic Dextran solutions, the cells oriented themselves at a constant angle to the flow and their membrane appeared to rotate about the interior. Although this behaviour was analogous to that of liquid drops, the concavity was still present in the deformed erythrocytes, whose mean major diameters in plasma increased by 1.05 µm as the shear stress increased from 0 to 0.4 N m-2. Deformation, through bending, was also observed with linear rouleaux of > 6 cells, here, at even the lowest shear stresses. By contrast, glutaraldehyde hardened cells and rouleaux rotated, without deforming, as rigid disks and rods respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nader, E., Skinner, S., Romana, M., Fort, R., Lemonne, N., Guillot, N., Gauthier, A., Antoine-Jonville, S., Renoux, C., Hardy-Dessources, M.-D., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01329 · Cited by 502
Motion of a tank-treading ellipsoidal particle in a shear flow
Keller, S. R., & Skalak, R. (1982) · Journal of Fluid Mechanics · doi:10.1017/s0022112082002651 · Cited by 460
Swinging of Red Blood Cells under Shear Flow
Abkarian, M., Faivre, M., & Viallat, A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.188302 · Cited by 341
Numerical Simulation of the Flow-Induced Deformation of Red Blood Cells
Pozrikidis, C. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1617985 · Cited by 284
Red cells’ dynamic morphologies govern blood shear thinning under microcirculatory flow conditions
Lanotte, L., Mauer, J., Mendez, S., Fedosov, D. A., Fromental, J.-M., Claveria, V., Nicoud, F., Gompper, G., & Abkarian, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608074113 · Cited by 268
Metadata
- Authors
- Goldsmith, H. L., Marlow, J., & MacIntosh, F. C.
- Venue
- Proceedings of the Royal Society of London. Series B. Biological Sciences
- Publisher
- The Royal Society
- Published
- 1972-10-10
- Volume
- 182
- Issue
- 1068
- Pages
- 351-384
- ISSN
- 0080-4649 (ISSN-L)
- 2053-9193
- OpenAlex
- W2027682565
- Cited by
- 220
- References
- 0
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.