CoChat

The caesium resonator as a standard of frequency and time

Essen, Louis, Parry, J. V. L. · 1957 · Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences
Cited by 101

The DOI matches its Crossref record.

Abstract

The construction, operation, and testing of the standard are described. The resonance employed is that due to the hyperfine splitting of caesium, having a frequency of approximately 9192 Mc/s. The transitions between the two atomic states F, mf (4,0) and F, mF (3, 0) are detected in an atomic-beam chamber, in which the length of the transition region is 47 cm, giving a width of resonance, at half deflexion, of 350 cycles, and a standard deviation of setting to the peak of the resonance of ± l c/s . It is shown that the geometrical parameters of the beam chamber such as slit widths, alinement of the beam, and shape of the pole-pieces of the deflecting magnets are relatively unimportant, and that other parameters, including the pressure in the beam chamber, the temperature of the oven, from which the caesium atoms are evaporated, and the radio-frequency power exciting the transitions can be varied throughout wide limits without causing changes in resonant frequency exceeding 1 part in 1010. A unidirectional magnetic field is applied over the transition region to remove the field-dependent resonant lines of the Zeeman pattern from the central line which depends on the field to only a second-order extent. It has been found that a satisfactory resonance is obtained with a field as low as 0.05 Oe at which the total effect of the field on the frequency is only 1 c/s. The dependence of the frequency on the phase conditions in the two-cavity resonators carrying the exciting field is studied, and it is concluded that the phases can be made sufficiently close to enable the frequency to be defined with a precision of ± 1 part in 1010. The resonator is used as a passive instrument to calibrate the quartz clocks, usually at intervals of a few days; and it is estimated that the clocks calibrated in this way provide at all times the atomic unit of frequency and time interval with a standard deviation of ± 2 parts in 1010. The quartz clocks are also calibrated in terms of astronomical time and the results are compared for the period from June 1955 to June 1956. For operational purposes the frequency of the resonance was taken as 9 192 631 830 c/s which was the value obtained in terms of the unit of uniform astronomical time made available by the Royal Greenwich Observatory in June 1955. The value is being determined in terms of the second of ephemeris time, which has now been adopted by the International Committee of Weights and Measures as the unit of time, but to obtain the accuracy required the comparison must be extended over a long interval in view of the difficulties associated with the astronomical measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rsta.1957.0010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Essen, L., & Parry, J. V. L.
Venue
Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences
Published
1957-08-08
Volume
250
Issue
973
Pages
45-69
ISSN
  • 0080-4614 (ISSN-L)
  • 2054-0272
OpenAlex
W2104031964
Cited by
101
References
0
FWCI
8.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.