CoChat

Modelling the pressure and force equilibrium in unipennate muscles with in-line tendons

Open access
Van Leeuwen, J. L., Spoor, C. W. · 1993 · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences
Cited by 47

The DOI matches its Crossref record.

Abstract

Several of the models proposed in the literature of unipennate muscles, which have two tendinous sheets and in-line tendons, cannot meet the criterion of mechanical stability. Based on the theory of Van Leeuwen & Spoor (Phil. Trans. R. Soc. Lond. B 336, 275-292 (1992)), we discuss how mechanically stable solutions for (planar) unipennate architectures could be obtained. A mathematical model is proposed in which the muscle architecture is generated numerically using the principles of mechanical stability and assuming that all muscle fibres shorten by the same relative amount. The tendinous sheets are attached tangentially to their respective tendons, as predicted from their low bending stiffness. The curvature, however, is discontinuous at the junction because of the sudden absence of muscle fibres from aponeurosis to tendon. In two of the muscle shapes generated, the sheets adjacent to the tendon show a region of negative curvature connected to a region of positive curvature. A sheet with a concave outer side is defined to have a negative curvature. In another example, two negative curvature regions are present with a positive region in-between. We show also a generated shape with a negative curvature of the sheets over their whole length. A good resemblance was found between the unipennate medial gastrocnemius muscle of the cat and a simulated architecture. The pressure distribution has also been calculated. With all muscle fibres exerting the same tensile stress of 200 kPa, a high pressure region is present in the centre of the muscle belly, half-way along its length. The highest pressures are predicted for muscles with long tendinous sheets, large attachment angles, and strongly curved fibres. Maximum pressures (2.40, 9.54, 10.47, and 7.57 kPa for the four discussed examples, and 15.05 kPa for the simulated gastrocnemius muscle) were at the lower side of the range as predicted previously for bipennate muscles and the unipennate medial gastrocnemius muscle of man (Van Leeuwen & Spoor 1992).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1098/rstb.1993.0162

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 47

Metadata

Authors
Van Leeuwen, J. L., & Spoor, C. W.
Venue
Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences
Published
1993-12-29
Volume
342
Issue
1302
Pages
321-333
ISSN
  • 0962-8436 (ISSN-L)
  • 1471-2970
OpenAlex
W2018934205
Cited by
47
References
0
FWCI
0.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modelling the pressure and force equilibrium in unipennate muscles with in-line tendons. https://app.cochat.ai/papers/10.1098/rstb.1993.0162
The paper
Van Leeuwen, J. L., & Spoor, C. W. (1993). Modelling the pressure and force equilibrium in unipennate muscles with in-line tendons. Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences. https://doi.org/10.1098/rstb.1993.0162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.