The DOI matches its Crossref record.
Modelling cartilage mechanobiology
Open accessAbstract
The growth, maintenance and ossification of cartilage are fundamental to skeletal development and are regulated throughout life by the mechanical cues that are imposed by physical activities. Finite element computer analyses have been used to study the role of local tissue mechanics on endochondral ossification patterns, skeletal morphology and articular cartilage thickness distributions. Using single–phase continuum material representations of cartilage, the results have indicated that local intermittent hydrostatic pressure promotes cartilage maintenance. Cyclic tensile strains (or shear), however, promote cartilage growth and ossification. Because single–phase material models cannot capture fluid exudation in articular cartilage, poroelastic (or biphasic) solid/fluid models are often implemented to study joint mechanics. In the middle and deep layers of articular cartilage where poroelastic analyses predict little fluid exudation, the cartilage phenotype is maintained by cyclic fluid pressure (consistent with the single–phase theory). In superficial articular layers the chondrocytes are exposed to tangential tensile strain in addition to the high fluid pressure. Furthermore, there is fluid exudation and matrix consolidation, leading to cell ‘flattening’. As a result, the superficial layer assumes an altered, more fibrous phenotype. These computer model predictions of cartilage mechanobiology are consistent with results of in vitro cell and tissue and molecular biology experiments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The absence of an ossified sternum in Archaeopteryx and Sapeornis is at odds with the interpretation that flapping flight induces cyclical tensile stress on cartilaginous sternal plates, causing calcification.
“The absence of an ossified sternum in Archaeopteryx (and Sapeornis ) is at odds with the interpretation that flapping flight would induce cyclical tensile stress on cartilaginous sternal plates, resulting in their calcification [32].”
From The ecology of Archaeopteryx (2026) · cites this paper as [32]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 52
- 10.1115/1.3138475 · DOI
- 10.1002/jor.1100120306 · DOI
- Beaupré G. S., 2000, Mechanobiology in the development, maintenance, and degeneration of articular cartilage, J. Rehabilitation Res. Dev., 37, 145
- 10.1063/1.1712886 · DOI
- Carter D. R., 1999, Linear elastic and poroelastic models of cartilage can produce comparable stress results: a comment on Tanck et al. ( J. Biomech. 32, 153-161, 1999, letter), J. Biomech., 32, 1255
- Carter D. & Beaupré G. 2001 Skeletal function and form: mechanobiology of skeletal development aging and regeneration. Cambridge University Press. · DOI
- 10.1002/jor.1100060604 · DOI
- Carter D. R., 1987, Influences of mechanical stress on prenatal and postnatal skeletal development, Clin. Orthop., 219, 237, 10.1097/00003086-198706000-00034 · DOI
- 10.3109/17453678709146498 · DOI
- 10.1007/s004290050291 · DOI
- 10.1016/S0021-9290(00)00034-8 · DOI
- 10.1002/jor.1100060602 · DOI
- 10.1016/0021-9290(78)90075-1 · DOI
- 10.1002/jor.1100170408 · DOI
- 10.1016/S8756-3282(02)00911-0 · DOI
- 10.1016/S0021-9290(99)00130-X · DOI
- 10.1078/0171-9335-00089 · DOI
- 10.1002/1529-0131(200111)44:11<2556::AID-ART436>3.0.CO;2-U · DOI
- Karvonen R. L., 1994, Factors affecting articular cartilage thickness in osteoarthritis and aging, J. Rheumatol., 21, 1310
- 10.1074/jbc.M101602200 · DOI
- Kurrat K., 1978, The thickness of the cartilage in the hip joint, J. Anat., 126, 145
- 10.1302/0301-620X.59B3.893504 · DOI
- 10.1016/S0045-7825(97)00208-9 · DOI
- 10.1177/00220345010800050601 · DOI
- 10.1115/1.2895693 · DOI
- 10.1002/jcp.10180 · DOI
- Mow V. & Ateshian G. 1997 Lubrication and wear of diarthrodial joints. In Basic orthopaedic biomechanics (ed. V. Mow & W. Hayes) pp. 275-315. Philadelphia PA: Lippencott-Raven.
- 10.1115/1.3138202 · DOI
- 10.1016/S0021-9290(96)00140-6 · DOI
- 10.1016/0021-9290(81)90041-5 · DOI
- 10.1016/0021-9290(81)90070-1 · DOI
- Sarin V. 2000 Mechanobiology of sesamoid formation development and ossification. PhD thesis Mechanical Engineering Stanford University Stanford CA USA.
- Shefelbine S. 2002 Mechanical regulation of bone growth fronts and growth plates. PhD thesis Mechanical Engineering Stanford University Stanford CA USA.
- 10.1016/S8756-3282(02)00700-7 · DOI
- 10.1002/jor.1100100111 · DOI
- 10.1002/jor.1100140110 · DOI
- 10.1016/S0021-9290(98)00105-5 · DOI
- 10.1115/1.1324669 · DOI
- 10.1114/1.239 · DOI
- 10.1115/1.2798330 · DOI
- 10.1016/S8756-3282(00)00459-2 · DOI
- Trindade M. C. D. Shida J. Ikenoue T. Yerby S. Goodman S. B. Schurman D. J. & Smith R. L. 2000 Intermittent hydrostatic pressure inhibits interleukin-6 and monocyte chemoattractant protein-1 expression by human osteoarthritic chondrocytes in vitro. In Trans. 46th Ann. Mtg Orthopaedic Res. Soc. Orlando FL 2000 vol. 25 p. 0175.
- Trueta J. 1968 Studies of the development and decay of the human frame. Philadelphia PA: W. B. Saunders.
- 10.1002/art.10462 · DOI
- 10.1053/joca.2002.0529 · DOI
- 10.1101/gad.815400 · DOI
- 10.1002/jor.1100150206 · DOI
- 10.1016/S0021-9290(00)00084-1 · DOI
- Wong M. Siegrist M. Goodwin K. & Park Y. D. 2002 Hydrostatic pressure tension and unconfined compression differentially regulate expression of cartilage matrix protein. In Trans. 48th Ann. Mtg Orthopaedic Res. Soc. Dallas TX 2002 vol. 27 p. 033.
- 10.1006/excr.2000.4847 · DOI
- Wu Q., 2001, Indian hedgehog is an essential component of mechanotransduction complex to stimulate chondrocyte proliferation, J. Biol. Chem., 276, 290
- 10.1002/(SICI)1097-4652(199909)180:3<402::AID-JCP11>3.0.CO;2-4 · DOI
Cited by
Sorted by citations
O’Connor, J. K., & Clark, A. D. (2026) · Discover Ecology · doi:10.1007/s44396-026-00026-z
Metadata
- Authors
- Carter, D. R., & Wong, M.
- Affiliations
- VA Palo Alto Health Care System (US)
- Institute for Biomedical Engineering, ETH, Gloriastrasse 35, 8092 Zurich, Switzerland
- Corresponding author
- Carter, Dennis R.
- Venue
- Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 2003-08-12
- Volume
- 358
- Issue
- 1437
- Pages
- 1461-1471
- ISSN
- 0962-8436 (ISSN-L)
- 1471-2970
- PMC
- PMC1693248
- OpenAlex
- W2076513735
- Cited by
- 177
- References
- 0
- Citations by year
- 2026: 5 · 2025: 3 · 2024: 9 · 2023: 6 · 2022: 7 · 2021: 10 · 2020: 6 · 2019: 9 · 2018: 9 · 2017: 9 · 2016: 11 · 2015: 9 · 2014: 9 · 2013: 10 · 2012: 10
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Philosophical Transactions of the Royal Society B Biological Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- cartilage mechanobiology, articular cartilage, endochondral ossification, cartilage growth, poroelasticity, fluid exudation, cyclic tensile strain, hydrostatic pressure, chondrocyte phenotype, cartilage thickness, joint mechanics, finite element analysis
- MeSH terms
- Animals, Biomechanical Phenomena, Cartilage, Computer Simulation, Humans, Models, Biological, Osteogenesis, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review