A Miniature Flow Cell Designed for Rapid Exchange of Media Under High-power Microscope Objectives
Abstract
The design, fabrication and use of a flow cell that allows rapid displacement of media viewed by short working distance, high power objectives are described. The cell has a small internal depth (about 0.04 cm), small volume (about 0.05 ml), and is chemically inert. It has been tested extensively in studies of tethered bacteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescent actin filaments move on myosin fixed to a glass surface.
Kron, S. J., & Spudich, J. A. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6272 · Cited by 853
Tracking kinesin-driven movements with nanometre-scale precision
Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988) · Nature · doi:10.1038/331450a0 · Cited by 819
Schnapp, B. J., Crise, B., Sheetz, M. P., Reese, T. S., & Khan, S. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.10053 · Cited by 41
Metadata
- Authors
- Berg, H. C., & Block, S. M.
- Venue
- Microbiology
- Publisher
- Microbiology Society
- Published
- 1984-11-01
- Volume
- 130
- Issue
- 11
- Pages
- 2915-2920
- ISSN
- 1350-0872 (ISSN-L)
- 1465-2080
- OpenAlex
- W2122585485
- Cited by
- 190
- References
- 0
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Miniature Flow Cell Designed for Rapid Exchange of Media Under High-power Microscope Objectives. https://app.cochat.ai/papers/10.1099/00221287-130-11-2915
- The paper
- Berg, H. C., & Block, S. M. (1984). A Miniature Flow Cell Designed for Rapid Exchange of Media Under High-power Microscope Objectives. Microbiology. https://doi.org/10.1099/00221287-130-11-2915
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.