Development and Types of Passive Samplers for Monitoring Atmospheric NO2 and NH3 Concentrations
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Numerous passive samplers based on the ‘Palmes-tube’ have been developed for ambient air monitoring. In each case, the diffusion path length and/or crosssectional area are modified to achieve the desired sampling rate. ‘Tube-type’ samplers are low sensitivity samplers suitable for long-term monitoring, whereas the ‘badge-type’ samplers have faster sampling rates suited to short-term monitoring. In the U.K., diffusion tubes are widely used for monitoring nitrogen dioxide (NO2) and ammonia (NH3). The open-ended diffusion tubes are prone to positive bias caused by incursion of wind eddies, leading to a shortening of the diffusion path. By using a porous membrane at the inlet, wind incursion is prevented, but an additional diffusion resistance is imposed and it is necessary to calibrate the tubes against a reference method to obtain an effective sampling rate. For NO2 sampling, positive bias also arises from the reaction of NO with O3 within the sampler. The interference from the chemical reaction is severe close to NO sources, with errors up to 30% for curbside locations when using the ‘tubetype’ sampler. In rural areas, where NO concentrations are small relative to NO2, these errors are small. In some implementations, there is also a negative bias over long sampling periods caused by the degradation of trapped NO2. The low sampling rates of diffusion tubes make them too uncertain for use at background NH3 concentrations (<1 μg NH3 m-3) where they significantly overestimate concentrations. Badge-type samplers such as the ‘Willems badge’ samplers permit accurate sampling at low ambient NH3 concentrations, but suffer from saturation at high concentrations and sensitivity to wind speed. A passive sampler optimised for monthly measurements of NH3 is reported here, together with its application in the U.K. National Ammonia Monitoring Network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Personal sampler for nitrogen dioxide
PALMES, E. D., GUNNISON, A. F., DiMATTIO, J., & TOMCZYK, C. (1976) · American Industrial Hygiene Association Journal · doi:10.1080/0002889768507522 · Cited by 514 · cited 11×
“NO2 is converted to nitrite ions after reaction with TEA, with conversion assumed to be 100%[38].”
BackgroundInfluentialCost-efficient techniques for urban- and background measurements of SO2 and NO2
Ferm, M., & Svanberg, P.-A. (1998) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00170-2 · Cited by 140 · cited 4×
“There are various reports that NO2 diffusion tubes exposed for 1 month consistently give lower NO2 concentrations than averaged NO2 concentrations from successive samples exposed for 1- or 2-week periods[26,32,39,40].”
BackgroundInfluentialMeasurements of Air Concentrations of SO2, NO2 and NH3 at Rural and Remote Sites in Asia
Ferm, M., & Rodhe, H. (1997) · Journal of Atmospheric Chemistry · doi:10.1023/a:1005816621522 · Cited by 113 · cited 6×
“Since NaAsO2 is highly toxic, the use of NaOH is preferable, and NO2 measurements using a sodium iodide (NaI) and NaOH mixture did not show NO2 underestimation for long exposure times when compared to weekly sampling[39].”
BackgroundMethodInfluentialSpatial and temporal variation of rural nitrogen dioxide concentrations across the United Kingdom
Atkins, D. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(94)00229-e · Cited by 67 · cited 3×
“Provided that the general guidelines for the location and exposure of the open diffusion tube are followed, wind speed has been considered to have minimal or negligible influence on its sampling rate because of the large length-to-area ratio of the tube[6,27].”
BackgroundSystematic Biases in Measurement of Urban Nitrogen Dioxide using Passive Diffusion Samplers
Heal, M. R., Kirby, C., & Cape, J. N. (2000) · Environmental Monitoring and Assessment · doi:10.1023/a:1006249016103 · Cited by 36 · cited 1×
“Predicted NO2 concentrations from the model agreed with measured NO2 concentrations in two independent studies in Edinburgh[35] and Cambridge[36], lending support to the hypothesis that reduced NO2 photolysis accounted for most of the excess NO2 measured with the passive samplers.”
BackgroundSelf-citation
Cited by
Effects of atmospheric ammonia (NH3) on terrestrial vegetation: a review
Krupa, S. V. (2003) · Environmental Pollution · doi:10.1016/s0269-7491(02)00434-7 · Cited by 956
Evidence for changing the critical level for ammonia
Cape, J. N., van der Eerden, L. J., Sheppard, L. J., Leith, I. D., & Sutton, M. A. (2009) · Environmental Pollution · doi:10.1016/j.envpol.2008.09.049 · Cited by 159
“For long-term averages, passive diffusion samplers provide adequate precision and accuracy (Leith et al., 2004, Sutton et al., 2001, Tang et al., 2001), but care must be taken with their deployment in the field.”
BackgroundSelf-citationHerrera, A., D’Imporzano, G., Zilio, M., Pigoli, A., Rizzi, B., Meers, E., Schouman, O., Schepis, M., Barone, F., Giordano, A., et al. (2022) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.1c07028 · Cited by 57
Metadata
- Authors
- Tang, Y. S., Cape, J. N., & Sutton, M. A.
- Venue
- The Scientific World JOURNAL
- Publisher
- Hindawi Limited
- Published
- 2001
- Volume
- 1
- Pages
- 513-529
- ISSN
- 1537-744X (ISSN-L)
- OpenAlex
- W2089996447
- Cited by
- 226
- References
- 5
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Types of Passive Samplers for Monitoring Atmospheric NO2 and NH3 Concentrations. https://app.cochat.ai/papers/10.1100/tsw.2001.82
- The paper
- Tang, Y. S., Cape, J. N., & Sutton, M. A. (2001). Development and Types of Passive Samplers for Monitoring Atmospheric NO2 and NH3 Concentrations. The Scientific World JOURNAL. https://doi.org/10.1100/tsw.2001.82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.