Fluorescence Perturbation Techniques to Study Mobility and Molecular Dynamics of Proteins in Live Cells: FRAP, Photoactivation, Photoconversion, and FLIP
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The technique of fluorescence recovery after photobleaching (FRAP) was introduced in the mid-1970s to study the diffusion of biomolecules in living cells. For several years, it was used mainly by a small number of biophysicists who had developed their own photobleaching systems. Since the mid-1990s, FRAP has gained increasing popularity because of the conjunction of two factors: First, photobleaching techniques are easily implemented on confocal laser-scanning microscopes (CLSMs), and so FRAP has become available to anyone who has access to such equipment. Second, the advent of green fluorescent protein (GFP) has allowed easy fluorescent tagging of proteins and their observation in living cells. Thanks both to the versatility of modern CLSMs, which allow control of laser intensity at any point of the image, and to the development of new fluorescent probes, additional photoperturbation techniques have emerged during the last few years. After the photoperturbation event, one observes and then analyzes how the fluorescence distribution relaxes toward the steady state. Because the photochemical perturbation of suitable fluorophores is essentially irreversible, changes of fluorescence intensity in the perturbed and unperturbed regions are due to the exchange of tagged molecules between those regions. This article first discusses the materials required for performing FRAP experiments on a CLSM and the software for data analysis. It then describes general considerations on how to perform FRAP experiments as well as the necessary controls. Finally, different possible ways to analyze the data are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering of a monomeric green-to-red photoactivatable fluorescent protein induced by blue light
Gurskaya, N. G., Verkhusha, V. V., Shcheglov, A. S., Staroverov, D. B., Chepurnykh, T. V., Fradkov, A. F., Lukyanov, S., & Lukyanov, K. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1191 · Cited by 725
Cited by
Accuracy and precision in quantitative fluorescence microscopy
Waters, J. C. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200903097 · Cited by 613
Shewan, A. M., Maddugoda, M., Kraemer, A., Stehbens, S. J., Verma, S., Kovacs, E. M., & Yap, A. S. (2005) · Molecular Biology of the Cell · doi:10.1091/mbc.e05-04-0330 · Cited by 371
Photobleaching of organic fluorophores: quantitative characterization, mechanisms, protection *
Demchenko, A. P. (2020) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/ab7365 · Cited by 370
Anselmi, F., Hernandez, V. H., Crispino, G., Seydel, A., Ortolano, S., Roper, S. D., Kessaris, N., Richardson, W., Rickheit, G., Filippov, M. A., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0800793105 · Cited by 340
Seeing is believing? A beginners' guide to practical pitfalls in image acquisition
North, A. J. (2006) · Journal of Cell Biology · doi:10.1083/jcb.200507103 · Cited by 257
Metadata
- Authors
- Bancaud, A., Huet, S., Rabut, G., & Ellenberg, J.
- Venue
- Cold Spring Harbor Protocols
- Publisher
- Cold Spring Harbor Laboratory
- Published
- 2010-12
- Volume
- 2010
- Issue
- 12
- Pages
- pdb.top90
- ISSN
- 1559-6095 (ISSN-L)
- 1940-3402
- OpenAlex
- W2317729913
- Cited by
- 128
- References
- 1
- Type
- posted content
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.