The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Statistical accuracy in fluorescence correlation spectroscopy
Abstract
Fluorescence correlation spectroscopy is a promising technique for the study of chemical kinetics and diffusion processes in small, well-defined sample volumes. Laser-induced fluorescence is used as a specific highly sensitive probe of concentration, permitting the analysis of the characteristic time dependence of spontaneous concentration fluctuations. We present here a quantitative analysis of the statistical and systematic errors inherent in such an experiment. Theoretical expressions are derived for the signal-to-noise ratio for various operational definitions of the photocount correlation signal. It is shown that the critical parameter governing the statistical accuracy of the experiment is not the total number of photocounts per correlation time, but (when background fluorescence is negligible) the photocounts per correlation time, per fluorescent molecule, a parameter independent of the number of fluorescent molecules in the sample volume. Comparisons are made with parallel results for laser-light scattering experiments derived by other authors. Finally, we consider the effects of background fluorescence, photolysis, and other deviations from ideality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Koppel, D. E. (1972) · The Journal of Chemical Physics · doi:10.1063/1.1678153 · Cited by 2,880
Self-citationThermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Intensity-Correlation Spectroscopy
Degiorgio, V., & Lastovka, J. B. (1971) · Physical Review A · doi:10.1103/physreva.4.2033 · Cited by 103
Cited by
Mobility measurement by analysis of fluorescence photobleaching recovery kinetics
Axelrod, D., Koppel, D. E., Schlessinger, J., Elson, E., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85755-4 · Cited by 2,714
Self-citationZero-Mode Waveguides for Single-Molecule Analysis at High Concentrations
Levene, M. J., Korlach, J., Turner, S. W., Foquet, M., Craighead, H. G., & Webb, W. W. (2003) · Science · doi:10.1126/science.1079700 · Cited by 1,378
Valence and patterning of aromatic residues determine the phase behavior of prion-like domains
Martin, E. W., Holehouse, A. S., Peran, I., Farag, M., Incicco, J. J., Bremer, A., Grace, C. R., Soranno, A., Pappu, R. V., & Mittag, T. (2020) · Science · doi:10.1126/science.aaw8653 · Cited by 1,147
Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)
Dertinger, T., Colyer, R., Iyer, G., Weiss, S., & Enderlein, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907866106 · Cited by 1,130
Rigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
Metadata
- Authors
- Koppel, D. E.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1974-12-01
- Volume
- 10
- Issue
- 6
- Pages
- 1938-1945
- ISSN
- 0556-2791 (ISSN-L)
- OpenAlex
- W2064757943
- Cited by
- 450
- References
- 5
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.