The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
All-optical versus electro-optical quantum-limited feedback
Open accessAbstract
All-optical feedback can be effected by putting the output of a source cavity through a Faraday isolator and into a second cavity which is coupled to the source cavity by a nonlinear crystal. If the driven cavity is heavily damped, then it can be adiabatically eliminated and a master equation or quantum Langevin equation derived for the first cavity alone. This is done for an input bath in an arbitrary state, and for an arbitrary nonlinear coupling. If the intercavity coupling involves only the intensity (or one quadrature) of the driven cavity, then the effect on the source cavity is identical to that which can be obtained from electro-optical feedback using direct (or homodyne) detection. If the coupling involves both quadratures, this equivalence no longer holds and a coupling linear in the source amplitude can produce a nonclassical state in the source cavity. The analogous electro-optic scheme using heterodyne detection introduces extra noise which prevents the production of nonclassical light. Unlike the electro-optical case, the all-optical feedback loop has an output beam (reflected from the second cavity). We show that this may be squeezed, even if the source cavity remains in a classical state.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carmichael, H. (1993) · Lecture Notes in Physics Monographs · doi:10.1007/978-3-540-47620-7 · Cited by 2,572
Gardiner, C. W. (1991) · Springer Series in Synergetics · doi:10.1007/978-3-662-09642-0 · Cited by 993
Cited by
Quantum Measurement and Control
Wiseman, H. M., & Milburn, G. J. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511813948 · Cited by 2,119
Self-citationControl of quantum phenomena: past, present and future
Brif, C., Chakrabarti, R., & Rabitz, H. (2010) · New Journal of Physics · doi:10.1088/1367-2630/12/7/075008 · Cited by 917
$H^{\infty}$ Control of Linear Quantum Stochastic Systems
James, M. R., Nurdin, H. I., & Petersen, I. R. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.929378 · Cited by 452
The Series Product and Its Application to Quantum Feedforward and Feedback Networks
Gough, J., & James, M. R. (2009) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2009.2031205 · Cited by 449
Lloyd, S. (2000) · Physical Review A · doi:10.1103/physreva.62.022108 · Cited by 389
Metadata
- Authors
- Wiseman, H. M., & Milburn, G. J.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1994-05-01
- Volume
- 49
- Issue
- 5
- Pages
- 4110-4125
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2039540991
- Cited by
- 206
- References
- 2
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.