Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 283

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Generation and detection of photons in a cavity with a resonantly oscillating boundary

Dodonov, V. V., Klimov, A. B. · 1996 · Physical Review A

Abstract

The problem of photon creation from vacuum in an ideal cavity with vibrating walls is studied in the resonance case, when the frequency of vibrations equals twice the frequency of some unperturbed electromagnetic mode. Analytical solutions are obtained in two cases: for the one-dimensional model (scalar electrodynamics) and for the three-dimensional (3D) cavity. In the first example, we have a strong intermode interaction; nonetheless, an explicit solution in terms of the complete elliptic integrals is found. The rate of photon generation in the principal mode rapidly assumes a constant value proportional to the product of the frequency by the dimensionless amplitude of oscillations. The total amount of photons created in all the modes increases in time as ${\mathit{t}}^{2}$. In the second example, the eigenmode spectrum is nonequidistant and the problem can be reduced to the problem of a single harmonic oscillator with a time-dependent frequency. The number of photons in the resonant mode of a 3D cavity increases exponentially in time and the field appears in a highly squeezed state with a strongly oscillating photon distribution function. The problem of detecting the created photons is analyzed in the framework of a simplified model, when a detector is replaced with a harmonic oscillator. It turns out that the presence of the detector changes the picture drastically: both the detector and the field mode occur in highly mixed (nonthermal) quantum states, with identical nonoscillating photon distribution functions. The detector gains exactly half of the total energy of excitation inside the cavity. The estimations show a possibility of creating up to several hundred or even thousand photons, provided that the cavity's Q factor exceeds ${10}^{10}$ and the amplitude of the wall's oscillations is greater than ${10}^{\mathrm{\ensuremath{-}}10}$ cm at a frequency of the order of 10 GHz. \textcopyright{} 1996 The American Physical Society.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.53.2664

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 283

Metadata

Authors
Dodonov, V. V., & Klimov, A. B.
Venue
Physical Review A
Published
1996-04-01
Volume
53
Issue
4
Pages
2664-2682
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W2015802002
Cited by
283
References
29
FWCI
6.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.